Sensors and detection
Industrial detection products connect physical conditions to control systems. The current published catalog includes SICK photoelectric sensors; detection families are grouped by their sensing role and exact model.
Browse categorySensors and detection products
Browse every published product classified in this category. Filter the list by model, condition or availability.
Showing 61–72 of 83

Sensors and detection
SICK IME12-08NNSZC0S IME M12 Inductive Sensor
IME12-08NNSZC0S
New Original
$54.66

Sensors and detection
SICK IME12-08NPSZC0K IME M12 Inductive Sensor
IME12-08NPSZC0K
New Original
$38.00

Sensors and detection
SICK IME12-08NPSZC0S IME M12 Inductive Sensor
IME12-08NPSZC0S
New Original
$55.25

Sensors and detection
SICK W4F DoubleLine Background-Suppression Sensor WTB4FT-32161120A00
WTB4FT-32161120A00
New Original
$352.31

Sensors and detection
SICK W4F DoubleLine Background-Suppression Sensor WTB4FT-38161120A00
WTB4FT-38161120A00
New Original
$328.00

Sensors and detection
SICK W4F Foreground-Suppression IO-Link Sensor WTF4FD-22162220A00
WTF4FD-22162220A00
New Original
$316.94

Sensors and detection
SICK W4F Foreground-Suppression Sensor WTF4FD-21311220ZZZ
WTF4FD-21311220ZZZ
New Original
$285.00

Sensors and detection
SICK W4F Photoelectric Sensor WTB4FP-2216R150A00
WTB4FP-2216R150A00
New Original
$281.00

Sensors and detection
SICK W4F Polarized Retro-Reflective IO-Link Sensor WLD4FP-22162130A00
WLD4FP-22162130A00
New Original
$152.91

Sensors and detection
SICK W4F Polarized Retro-Reflective Sensor WLD4FP-213121A0ZZZ
WLD4FP-213121A0ZZZ
New Original
$278.00

Sensors and detection
SICK W4F Through-Beam Sensor Set WSE4FP-22162100A00
WSE4FP-22162100A00
New Original
$280.01

Sensors and detection
SICK W4F V-Optics IO-Link Sensor WTV4FE-1H162120A00
WTV4FE-1H162120A00
New Original
$305.00
Browse products and selection paths
Use the current product families or the selection checklist to narrow the requirement.
Product family
SICK W4F Photoelectric Sensors
SICK W4F miniature photoelectric sensors combine compact housings with specialized optics for background suppression, foreground suppression, transparent-object detection, retro-reflective sensing and through-beam applications.
Selection guidance
Selection checklist
Optical principle, target characteristics and electrical interface determine whether a sensor fits the application. A similar housing does not establish equivalent behavior.
Product families in this category
Browse the published collections associated with this product role.
DFS60B S4 Solid-Shaft Incremental Encoders
SICK DFS60B incremental encoders with S4 face-mount flange and 10 mm ×19 mm flat solid shaft. Compare fixed TTL/RS-422, HTL/push-pull and programmable TTL/HTL versions by resolution, supply and connection.
View collectionIME Inductive Proximity Sensors
SICK IME cylindrical inductive proximity sensors for non-contact metal detection. The first selection covers ten M8/M12, DC 3-wire normally-open models with PNP/NPN outputs and flush/non-flush installation.
View collectionSearchline Excel Plus Open Path Gas Detectors
Honeywell Searchline Excel Plus complete open-path hydrocarbon gas detector systems for 2–120 m coverage. Compare the stainless-steel M25 and ¾-inch NPT kits, with transmitter, receiver, universal mounts and plastic sunshades.
View collectionSearchpoint Optima Plus Point Infrared Gas Detectors
Honeywell Searchpoint Optima Plus point-infrared flammable gas detectors. Select hydrocarbon or ethylene optics, gas calibration, approval and mounting thread, HART or analog output, and an optional factory-fitted remote gassing cell.
View collectionSensepoint XCD Gas Detectors
Complete Honeywell Sensepoint XCD fixed gas detectors with local display, 4–20 mA output and alarm/fault relays. Compare gas, sensing technology, enclosure material, entry thread and communication configuration—not sensor cartridges alone.
View collectionSensepoint XCL Gas Detectors
Honeywell Sensepoint XCL single-sensor fixed gas detectors for commercial and light-industrial ordinary locations. Compare gas range, analog or Modbus interface, optional relay hardware and Bluetooth-enabled commissioning. Separate from hazardous-area XRL detectors.
View collectionSICK W4F Photoelectric Sensors
SICK W4F miniature photoelectric sensors combine compact housings with specialized optics for background suppression, foreground suppression, transparent-object detection, retro-reflective sensing and through-beam applications.
View collectionW9 Miniature Photoelectric Sensors
SICK W9 miniature photoelectric sensors cover proximity, retro-reflective and through-beam detection. This initial selection focuses on WTB9-3 visible-red background-suppression sensors with PNP/NPN outputs and fixed cable, M8/M12 or pigtail connections.
View collectionXNX Universal Transmitters
Honeywell XNX configurable fixed-gas transmitter platform with EC, mV or IR sensor interfaces. Choose enclosure, approval, entry thread and output options around the sensing technology and receiving control system.
View collectionDefine what the sensor must detect
Optical principle, target characteristics and electrical interface determine whether a sensor fits the application. A similar housing does not establish equivalent behavior.
- 01
Match the sensing principle
Identify the actual detection task and the optical principle stated for the exact sensor model.
- Target and background
- Optical principle
- Required sensing range
- 02
Check the electrical interface
Compare supply, output type, connector or cable and any communication interface.
- Supply voltage
- Switching output
- Connector pin assignment
- 03
Review mounting and target conditions
Check available mounting space, target material and the effect of surrounding surfaces.
- Mounting geometry
- Target characteristics
- Background conditions
Where this equipment fits
Follow the component role through the installed automation system.
Target or physical condition
Sensing element
Electrical output
I/O input
Control logic
Planning a replacement
Capture the installed model and application context before selecting replacement equipment.
- 01
Record the full sensor model, output type and connection details.
- 02
Document the sensing distance, target and mounting arrangement.
- 03
Check the exact model datasheet before replacing a sensor with a similar housing.
Sensors and detection questions
Practical checks for identifying, selecting and replacing controller hardware.
Are standard photoelectric sensors suitable as safety switches?
A standard detection sensor must not be treated as a safety device. Use equipment specified for the required safety function and the engineered safety system.
Need help sourcing sensors and detection?
Send the manufacturer, complete order number, required condition, quantity and delivery destination for a tailored quotation.
Request a quote