Skip to content

I/O and signal modules

Digital input and output modules connect field signals to an industrial controller. Browse EtherCAT terminals, ET 200SP distributed I/O and S7-1200 signal modules by platform, signal direction and channel requirements.

Browse category

I/O and signal modules products

Browse every published product classified in this category. Filter the list by model, condition or availability.

Showing 13–24 of 24

Siemens SIMATIC S7-1200 SM 1222 digital output module 6ES7222-1BH32-0XB0 front view

I/O and signal modules

Siemens SIMATIC S7-1200 SM 1222 16 DO 24 V DC 6ES7222-1BH32-0XB0

6ES7222-1BH32-0XB0

New Original

$999.00

In Stock
Siemens SIMATIC S7-1200 SM 1223 digital input and relay output module 6ES7223-1PH32-0XB0 front view

I/O and signal modules

Siemens SIMATIC S7-1200 SM 1223 8 DI / 8 Relay DO 6ES7223-1PH32-0XB0

6ES7223-1PH32-0XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1221 manufacturer family reference image; verify SIPLUS 6AG1221-1BH32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1221 16 DI 6AG1221-1BH32-4XB0

6AG1221-1BH32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1221 manufacturer family reference image; verify SIPLUS 6AG1221-1BF32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1221 8 DI 6AG1221-1BF32-4XB0

6AG1221-1BF32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1222 manufacturer family reference image; verify SIPLUS 6AG1222-1BH32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1222 16 DQ 6AG1222-1BH32-4XB0

6AG1222-1BH32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1222 manufacturer family reference image; verify SIPLUS 6AG1222-1HH32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1222 16 DQ Relay 6AG1222-1HH32-4XB0

6AG1222-1HH32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1222 manufacturer family reference image; verify SIPLUS 6AG1222-1BF32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1222 8 DQ 6AG1222-1BF32-4XB0

6AG1222-1BF32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1222 manufacturer family reference image; verify SIPLUS 6AG1222-1HF32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1222 8 DQ Relay 6AG1222-1HF32-4XB0

6AG1222-1HF32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1223 manufacturer family reference image; verify SIPLUS 6AG1223-1BL32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1223 16 DI / 16 DQ 6AG1223-1BL32-4XB0

6AG1223-1BL32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1223 manufacturer family reference image; verify SIPLUS 6AG1223-1BH32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1223 8 DI / 8 DQ 6AG1223-1BH32-4XB0

6AG1223-1BH32-4XB0

New Original

$999.00

In Stock
Siemens S7-1200 SM 1223 manufacturer family reference image; verify SIPLUS 6AG1223-1PH32-4XB0 by its full order number

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1223 8 DI / 8 DQ Relay 6AG1223-1PH32-4XB0

6AG1223-1PH32-4XB0

New Original

$999.00

In Stock
Siemens SIPLUS S7-1200 SM 1226 F-DQ module 6AG1226-6DA32-5XB0

I/O and signal modules

Siemens SIPLUS S7-1200 SM 1226 F-DQ 6AG1226-6DA32-5XB0

6AG1226-6DA32-5XB0

New Original

$478.15

In Stock

Specify the signal and the host system together

An I/O module must match both the controller or coupler platform and the electrical behavior of the field circuit.

  1. 01

    Match the host platform

    Identify the controller, bus coupler and terminal or BaseUnit system before selecting a module.

    • Host family
    • Bus or backplane
    • BaseUnit or terminal arrangement
  2. 02

    Define each field signal

    Record input or output direction, signal voltage, channel count and sensor or load wiring.

    • Digital input or output
    • Signal voltage
    • Channel count
  3. 03

    Check channel and installation limits

    Compare input thresholds or output load limits, grouping, isolation and terminal requirements using the exact module documentation.

    • Input behavior
    • Load rating
    • Terminal assignment

Where this equipment fits

Follow the component role through the installed automation system.

01

Sensors and switches

02

Field wiring

03

I/O terminal or module

04

Coupler or backplane

05

Controller

Planning a replacement

Capture the installed model and application context before selecting replacement equipment.

  • 01

    Record the complete I/O module order number and host platform.

  • 02

    Preserve terminal assignments, channel grouping and wiring documentation.

  • 03

    Check the replacement module configuration and parameter settings.

I/O and signal modules questions

Practical checks for identifying, selecting and replacing controller hardware.

Can EtherCAT terminals and ET 200SP modules be interchanged?

They belong to different I/O systems. Select the module for its supported coupler, backplane and terminal arrangement; equal channel counts do not establish compatibility.

Need help sourcing i/o and signal modules?

Send the manufacturer, complete order number, required condition, quantity and delivery destination for a tailored quotation.

Request a quote