5069-OB8
5069-OB8 Compact 5000 high-current dc output module. Eight sourcing DC outputs in two groups of four, rated 2 A per channel and powered through local actuator connections. Requires a separately ordered 5069-RTB18 terminal block.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Allen-Bradley. Brand names are used for identification and compatibility purposes only. Read disclaimer
Signal ratings, field-power arrangement and terminal wiring for 5069-OB8.
5069-OB8 is an Allen-Bradley Compact 5000 standard digital I/O module. Eight sourcing DC outputs in two groups of four, rated 2 A per channel and powered through local actuator connections. It expands a compatible Logix system; it is not a CPU, Ethernet adapter or safety I/O module.
5069-OB8
8
10–32 V DC
24 V DC
2 A per channel; 8 A per group; 16 A per module
OUT0–3 on LA0; OUT4–7 on LA1
0.25 V DC
0.5 mA per point
1 mA
≤100 µs at 25 °C and 2 A
4 A for 10 ms, repeatable every 2 s
LA0 supplies channels 0–3 and LA1 supplies channels 4–7. The module can provide higher per-channel current than OB16, but the field supply and conductors must support the 8 A group and 16 A module limits. Supported diagnostics include field-power loss, no load and output short-circuit/overload/overtemperature; protection does not replace the branch protection design.
Each output can be configured to turn off, turn on or hold its last state; off is the default. Fault-mode duration is also configurable. Set these behaviors deliberately for the connected actuator. These standard outputs do not replace a safety-rated output function.
75 mA at 18–32 V DC
No SA current draw; DC SA bus required
3.2 W
5069-RTB18-SPRING or 5069-RTB18-SCREW; ordered separately
0.4 N·m
0.34–1.5 mm² (22–16 AWG), copper, ≥105 °C
10 mm spring RTB; 12 mm screw RTB
The module electronics draw MOD power, while the outputs take field power from the LA terminals on the module RTB. This module does not draw SA current, but it must still be installed on a DC SA segment. LA power is not a reason to place a DC module on an AC SA bus.
Feed the LA0 and LA1 power terminals on the RTB. Each group has its own positive supply and return connections as shown in the original diagram. The module passes DC SA power onward but does not use that bus to supply the actuator outputs.
Rockwell Automation 5069-TD001P-EN-P, March 2026, p.13. Terminal assignment and field-power connections.
Compact 5000 I/O modules do not include the removable terminal block. Choose either the 18-position spring or screw RTB for the wiring method. Both use one wire per terminal; the screw torque applies to the screw RTB, not the spring mechanism.
Install these 5069 modules to the right of a compatible CompactLogix 5380, CompactLogix 5480 or Compact GuardLogix 5380 controller, or use a supported Compact 5000 EtherNet/IP adapter for a remote I/O station. Add the correct module profile and electronic keying in Studio 5000 Logix Designer. A remote station needs its adapter; the I/O module itself has no standalone Ethernet connection.
144.6 × 22 × 105.4 mm
1 standard Compact 5000 slot
175 g
0 to +60 °C
−40 to +85 °C
5–95%, noncondensing
Open style; enclosed installation required
EN50022, 35 × 7.5 mm, compatible zinc-plated steel
For local CompactLogix 5380 systems, mount the I/O assembly horizontally. System clearances depend on the controller and operating temperature: standard CompactLogix 5380 guidance is 50.8 mm at 50/55 °C and 101.6 mm at 60 °C. A standard-only adapter system uses 25.4 mm on all sides; adding safety modules changes the system clearance. Finish the last module with the system end cap.
Compact 5000 5069 modules are not 1769 Compact I/O or 1734 POINT I/O plug-in replacements. Match input/output role, signal type, terminal assignment, software profile and power segment. A matching channel count alone does not establish interchangeability.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.