Allen-Bradley Compact 5000 Digital I/O Modules
Allen-Bradley 5069 standard digital I/O for compatible Logix systems. The first batch includes AC/DC inputs, standard and fast DC outputs, high-current outputs and isolated relay outputs.
View productsChoose the signal, output technology and field-power arrangement
Compare ten selected standard 5069 modules. The first batch excludes controllers, EtherNet/IP adapters, analog and safety I/O, conformal-coated K variants and accessories. Other standard digital members, including 32-channel models and OW16, remain outside this initial selection.
Showing 1–10 of 10

I/O and signal modules
Allen-Bradley 5069-IA16 Compact 5000 AC Input Module
5069-IA16
New Original
$574.93

I/O and signal modules
Allen-Bradley 5069-IB16 Compact 5000 DC Sinking Input Module
5069-IB16
New Original
$379.59

I/O and signal modules
Allen-Bradley 5069-IB16F Compact 5000 Fast DC Sinking Input Module
5069-IB16F
New Original
$435.00

I/O and signal modules
Allen-Bradley 5069-IB6F-3W Compact 5000 3-Wire Fast DC Input Module
5069-IB6F-3W
New Original
$798.52

I/O and signal modules
Allen-Bradley 5069-OA16 Compact 5000 AC Output Module
5069-OA16
New Original
$1,035.83

I/O and signal modules
Allen-Bradley 5069-OB16 Compact 5000 DC Sourcing Output Module
5069-OB16
New Original
$601.00

I/O and signal modules
Allen-Bradley 5069-OB16F Compact 5000 Fast DC Sourcing Output Module
5069-OB16F
New Original
$694.00

I/O and signal modules
Allen-Bradley 5069-OB8 Compact 5000 High-Current DC Output Module
5069-OB8
New Original
$390.00

I/O and signal modules
Allen-Bradley 5069-OW4I Compact 5000 Isolated NO Relay Output Module
5069-OW4I
New Original
$302.00

I/O and signal modules
Allen-Bradley 5069-OX4I Compact 5000 Isolated Changeover Relay Output Module
5069-OX4I
New Original
$580.00
Standard digital I/O by field task
Choose the circuit role before comparing channel count. Shared-family mechanics do not make AC, DC and relay circuits interchangeable.
AC and sinking DC inputs
IA16 accepts AC signals. IB16 and IB16F provide sixteen DC inputs; IB6F-3W exchanges channel density for six complete sensor input/supply/return groups.
Solid-state outputs
OA16 switches AC. OB16 and OB16F provide sixteen 0.5 A sourcing DC outputs, while OB8 provides eight 2 A sourcing outputs in two groups.
Individually isolated relay outputs
OW4I provides four normally-open Form A channels. OX4I provides four Form C changeover channels; its NO and NC contacts do not create eight independent outputs.
Three decisions shape the station
Signal type, timing and field-power distribution determine the module and wiring selection.
- 01
Match the signal and load technology
Separate AC signals, sinking DC inputs, sourcing DC outputs and dry relay contacts.
- Sinking inputs accept sourcing field signals.
- Per-channel and whole-module output limits both apply.
- Relay DC make/break ratings vary with load voltage.
- 02
Use fast I/O where its functions matter
F modules change timing and supported features; they do not automatically increase channel current.
- IB16F and IB6F-3W support pulse latching and pattern matching.
- OB16F supports scheduled outputs.
- CIP Sync time functions need a system leader clock.
- 03
Build the power groups and terminal order
MOD electronics, SA field distribution and LA actuator supplies have distinct roles.
- Use an FPD to separate AC and DC SA groups.
- OB8 and OB16/OB16F use local LA connections.
- Order 5069-RTB18-SPRING or 5069-RTB18-SCREW separately.

