Pilz PNOZmulti 2 Configurable Safety Controllers
Pilz PNOZmulti 2 configurable safety controllers for machine safety logic. The initial selection covers PNOZ m C0, B0, B0.1 and B1 base units: standalone I/O, digital expansion and modular systems with distinct storage and connection arrangements.
View productsChoose the safety base before expanding the I/O
Start with the onboard input/output count, expansion role and project handling. This selection covers four conventional base-unit orders; burner-specific bases, revision bundles and separately ordered expansion modules have their own selection requirements.
Showing 1–4 of 4

Safety control
Pilz 772100 PNOZ m B0 Safety Controller
772100
New Original
$571.08

Safety control
Pilz 772101 PNOZ m B1 Safety Controller
772101
New Original
$1,001.82

Safety control
Pilz 772104 PNOZ m B0.1 Safety Controller
772104
New Original
$737.21

Safety control
Pilz 772105 PNOZ m C0 Safety Controller
772105
New Original
$585.00
Three base-unit roles
Start with a standalone, onboard-I/O or modular base, then size the sensor and actuator channels for the safety project.
PNOZ m C0 — compact standalone safety
772105 provides up to eight safe inputs and four safe semiconductor outputs in 22.5 mm. No physical expansion modules; LED diagnostics and USB project transfer.
PNOZ m B0 and B0.1 — onboard I/O with expansion
772100 and 772104 each provide 12 fixed safe inputs plus eight configurable input/auxiliary channels and four safe outputs in 45 mm. Their expansion and firmware capabilities remain distinct.
PNOZ m B1 — modular I/O and Ethernet
772101 supplies the safety CPU, two switched Ethernet ports, USB project memory and four test-pulse outputs. Safe sensor inputs and actuator outputs come from expansion modules.
Match the order to the safety project
I/O counts, firmware, terminal sets and project storage distinguish base units with similar family names.
- 01
Count input and output functions
Configurable input/auxiliary channels count within the eight-input C0 or twenty-input B0/B0.1 maximum. Using them as auxiliary outputs reduces safe-input capacity. Test-pulse outputs are a separate function.
- 02
Retain the device and firmware version
772100 is listed with firmware 2.6 and excludes PDP67 orders 772600, 772601, 772610 and 772611. The newer B0 revision bundle is order 772714. B0.1 project storage also changes with the device version.
- 03
Include terminals and project storage
Plug-in screw and spring-loaded terminal sets are separately selected. Legacy B0 needs a project chip card; B1 uses the supplied Pilz USB memory. C0 uses USB transfer with an optional chip card.
- 04
Keep specialised orders separate
This collection starts with four conventional base units. PNOZmulti Mini, Classic controllers, burner base 772102, revision bundle 772714 and expansion/accessory modules are outside this initial product selection.