Skip to content
Pilz PNOZ m C0 configurable safety base unit

Pilz 772105 PNOZ m C0 Safety Controller

772105

Standalone PNOZmulti 2 safety controller in a 22.5 mm housing. Six fixed inputs plus two configurable channels provide up to eight safe inputs; four safe semiconductor outputs support compact machine safety circuits. No physical expansion modules.

Availability
In Stock
Condition
New Original
SKU
772105
Lifecycle
Active
$585.00
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Pilz. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Safety I/O, engineering dependencies and installation for PNOZ m C0 (772105).

A standalone configurable safety controller

772105 is the compact standalone choice for a safety circuit that fits within eight safe inputs and four safe semiconductor outputs. It brings configurable safety logic to a 22.5 mm rail width without side-mounted expansion modules. LED status indication replaces the larger display found on the B0 and B1 bases.

Base-unit capacity

Manufacturer article

772105

Product designation

PNOZ m C0

Platform

PNOZmulti 2

Role

Standalone; no physical expansion modules

Fixed safe digital inputs

6

Configurable input / auxiliary-output channels

2

Counted within the maximum safe input capacity, not extra inputs.

Maximum onboard safe inputs

8

Safe semiconductor outputs

4

Positive-switching, single-pole outputs; 24 V DC, 2 A per output.

Total output-current derating

133 mA per °C above 45 °C

8 A at 45 °C before derating; includes the load-current limit for the installed ambient.

Test-pulse outputs

2

Configurable as test-pulse or auxiliary outputs; 0.1 A.

Engineering software

PNOZmulti Configurator

Count configurable channels only once

The 6 fixed safe inputs and 2 configurable input/auxiliary channels provide up to 8 safe inputs when every configurable channel is used as an input. Assigning one of those channels as a non-safety auxiliary output reduces the available safe-input count. The 2 test-pulse channels are a separate group.

Safety capability follows the circuit design

The platform supports safety functions up to PL e / Category 4 and SIL 3 in suitable architectures. The achieved level follows the input circuit, logic, output arrangement and reaction-time calculation for the complete safety function. Configure the sensor evaluation and output diagnostics for that design.

Supply and connection data

Nominal supply

24 V DC

Voltage tolerance

−20% / +25%

Supply arrangement

Common module and output supply

Supply/output isolation

No galvanic separation between input/output and module supply

Connection terminals

Plug-in screw or spring-loaded type

Terminal sets are separately selected accessories.

Screw / spring terminal set

750004 / 751004

X1

Inputs I4–I7

X2

Safe semiconductor outputs O0–O3

X3

Configurable IM0 / IM1 and inputs I2 / I3

X4

Test-pulse/auxiliary T0M20 / T1M21; 24 V / 0 V supply

Manufacturer front view and terminal legend

1006013-EN-05, page 8. Original front view with connection legend and device/version markings.

PNOZ m C0 manufacturer terminal map and front-view legend

PNOZ m C0 manufacturer terminal map and front-view legend

1006013-EN-05, page 8. Original front view with connection legend and device/version markings.

Size the module supply for the switched loads

The C0 uses one 24 V module supply for the device and its semiconductor outputs. Include the connected output load when sizing the supply. The manual’s 8.5 A / 204 W maximum external-supply figure is a load-supply requirement; the module’s maximum heat dissipation is 4 W.

Use test pulses for input monitoring

Test-pulse wiring allows the configured system to detect shorts across input circuits. When assigned as test outputs, these terminals serve the input test arrangement rather than external actuator loads. The wiring and selected input functions form one circuit in the Configurator project.

Project storage and diagnostics

Configure and transfer the safety project using PNOZmulti Configurator and the Mini-B USB connection. A chip card is optional for project transfer. The software-generated circuit defines which inputs implement each safety function and how the outputs respond; the LED indications identify run, diagnostic and I/O fault states.

Standalone and cascading boundary

C0 does not accept physical expansion modules. Its input and output channels can support configured cascading signals, but cascading is a designed safety connection between systems rather than an extra local I/O bank. The two configurable input/auxiliary channels are included within the eight-input maximum.

Mechanical and operating envelope

Height × width × depth

101.4 × 22.5 × 120 mm

Manufacturer technical-data dimensions.

Net weight

105 g

Mounting

Horizontal on DIN rail

Housing / terminals

IP20

Installation area

IP54 control cabinet

Operating ambient

0 to +65 °C

Forced cabinet convection from 55 °C.

Storage ambient

−25 to +70 °C

Maximum operating altitude

2000 m

Condensation

Not permitted

Project storage

USB project transfer; optional 8 kB / 32 kB chip card

Mounting outline

1006013-EN-05, page 23. Original dimensional drawing; retain the indicated orientation and terminal-dependent dimensions.

PNOZ m C0 manufacturer dimensional drawing with all original dimensions

PNOZ m C0 manufacturer dimensional drawing with all original dimensions

1006013-EN-05, page 23. Original dimensional drawing; retain the indicated orientation and terminal-dependent dimensions.

Complete the configured device order

Choose screw terminal set 750004 or spring-loaded set 751004 for the C0. A chip card is an optional project-transfer accessory. Leave access to the USB connection and field wiring; the 22.5 mm body does not include a physical expansion bus for extra I/O modules.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.