Skip to content
Pilz PNOZ m B0 configurable safety base unit

Pilz 772100 PNOZ m B0 Safety Controller

772100

Expandable PNOZmulti 2 base unit with up to 20 safe inputs and four safe semiconductor outputs. A 45 mm-wide controller for machine safety logic, with display diagnostics and USB project transfer. This 772100 order is the firmware 2.6 version.

Availability
In Stock
Condition
New Original
SKU
772100
Lifecycle
Active
$571.08
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Pilz. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Safety I/O, engineering dependencies and installation for PNOZ m B0 (772100).

An expandable safety base with onboard I/O

772100 evaluates a configurable safety circuit using the inputs and outputs on the base unit and supported expansion modules. It is useful where a machine needs more configurable logic than individual fixed-function safety relays, while retaining onboard I/O in the base unit.

Base-unit capacity

Manufacturer article

772100

Product designation

PNOZ m B0

Platform

PNOZmulti 2

Role

Expandable PNOZmulti 2 base; module arrangement follows the configured system

Fixed safe digital inputs

12

Configurable input / auxiliary-output channels

8

Counted within the maximum safe input capacity, not extra inputs.

Maximum onboard safe inputs

20

Safe semiconductor outputs

4

Positive-switching, single-pole outputs; 24 V DC, 2 A per output.

Combined safe / auxiliary output loading

6 A / 400 mA, 7 A / 200 mA, or 8 A / 0 mA

Maximum paired totals from the manufacturer output-current curve; each safe output remains limited to 2 A.

Test-pulse outputs

4

Configurable as test-pulse or auxiliary outputs; 0.1 A.

Engineering software

PNOZmulti Configurator

Count configurable channels only once

The 12 fixed safe inputs and 8 configurable input/auxiliary channels provide up to 20 safe inputs when every configurable channel is used as an input. Assigning one of those channels as a non-safety auxiliary output reduces the available safe-input count. The 4 test-pulse channels are a separate group.

Safety capability follows the circuit design

The platform supports safety functions up to PL e / Category 4 and SIL 3 in suitable architectures. The achieved level follows the input circuit, logic, output arrangement and reaction-time calculation for the complete safety function. Configure the sensor evaluation and output diagnostics for that design.

Supply and connection data

Nominal supply

24 V DC

Voltage tolerance

−20% / +25%

Supply arrangement

System A1/A2 plus separate 24 V / 0 V semiconductor-output supply

Supply/output isolation

Output supply galvanically isolated from system supply

Connection terminals

Plug-in screw or spring-loaded type

Terminal sets are separately selected accessories.

Screw / spring terminal set

750008 / 751008

X1

Inputs I8–I15

X2

T0M20–T3M23; safe semiconductor outputs O0–O3

X3

Configurable IM0–IM3; inputs I4–I7

X4

Configurable IM16–IM19; supply connections

Manufacturer front view and terminal legend

PNOZmulti 2 catalogue 1006421-EN-01, page 55. Front views with and without the cover; the full terminal legend is retained.

PNOZ m B0 manufacturer terminal map and front-view legend

PNOZ m B0 manufacturer terminal map and front-view legend

PNOZmulti 2 catalogue 1006421-EN-01, page 55. Front views with and without the cover; the full terminal legend is retained.

Provide both system and output power

Connect the system supply at A1/A2 and the semiconductor-output supply at the separate 24 V / 0 V connections. The output supply remains necessary even if no safe outputs are used. Use the marked supply arrangement rather than treating the output terminal as an interchangeable system-power input.

Use test pulses for input monitoring

Test-pulse wiring allows the configured system to detect shorts across input circuits. When assigned as test outputs, these terminals serve the input test arrangement rather than external actuator loads. The wiring and selected input functions form one circuit in the Configurator project.

Project storage and diagnostics

The firmware 2.6 base uses an 8 kB or 32 kB PNOZmulti chip card to hold the safety project. The configuration and actual module arrangement must match the project before it is activated. USB supports project transfer; the front display and LEDs provide device and I/O diagnostics.

772100 firmware and PDP67 boundary

Pilz lists order 772100 with firmware 2.6. It cannot be combined with PDP67 orders 772600, 772601, 772610 or 772611. The newer-function B0 bundle uses order 772714, so a B0 name alone does not establish the same firmware capabilities.

Mechanical and operating envelope

Height × width × depth

101.4 × 45 × 120 mm

Manufacturer technical-data dimensions.

Net weight

235 g

Mounting

Horizontal on DIN rail

Housing / terminals

IP20

Installation area

IP54 control cabinet

Operating ambient

0 to +60 °C

Forced cabinet convection from 55 °C.

Storage ambient

−25 to +70 °C

Maximum operating altitude

2000 m

Condensation

Not permitted

Project storage

Chip card required for the firmware 2.6 base unit

Mounting outline

Catalogue 1006421-EN-01, page 57. Original outline; dimensions in mm with inch equivalents. The starred dimension refers to spring-loaded terminals.

PNOZ m B0 manufacturer dimensional drawing with all original dimensions

PNOZ m B0 manufacturer dimensional drawing with all original dimensions

Catalogue 1006421-EN-01, page 57. Original outline; dimensions in mm with inch equivalents. The starred dimension refers to spring-loaded terminals.

Complete the configured device order

Choose screw terminal set 750008 or spring-loaded set 751008 for PNOZ m B0. Include the configured digital I/O or other supported modules for the selected base version, and retain terminators at unused expansion interfaces. Include the required project chip card for the firmware 2.6 unit.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.