Exact product identification
Your quotation references the complete manufacturer part number to keep the requested product clear.

772104
PNOZmulti 2 base unit with 12 fixed safe inputs, eight configurable input/auxiliary channels and four safe semiconductor outputs. Digital I/O expansion, display diagnostics and a 45 mm housing suit compact machine safety systems.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Pilz. Brand names are used for identification and compatibility purposes only. Read disclaimer
Safety I/O, engineering dependencies and installation for PNOZ m B0.1 (772104).
772104 combines the B0-style 20-input maximum and four safe outputs with a digital I/O expansion role. It suits machine safety circuits that need configurable E-stop, guard or optoelectronic input logic plus additional digital channels, without selecting a B1 modular CPU as the starting point.
772104
PNOZ m B0.1
PNOZmulti 2
Expandable with supported digital input/output modules
12
8
Counted within the maximum safe input capacity, not extra inputs.
20
4
Positive-switching, single-pole outputs; 24 V DC, 2 A per output.
6 A / 400 mA, 7 A / 200 mA, or 8 A / 0 mA
Maximum paired totals from the manufacturer output-current curve; each safe output remains limited to 2 A.
4
Configurable as test-pulse or auxiliary outputs; 0.1 A.
PNOZmulti Configurator
The 12 fixed safe inputs and 8 configurable input/auxiliary channels provide up to 20 safe inputs when every configurable channel is used as an input. Assigning one of those channels as a non-safety auxiliary output reduces the available safe-input count. The 4 test-pulse channels are a separate group.
The platform supports safety functions up to PL e / Category 4 and SIL 3 in suitable architectures. The achieved level follows the input circuit, logic, output arrangement and reaction-time calculation for the complete safety function. Configure the sensor evaluation and output diagnostics for that design.
24 V DC
−20% / +25%
System A1/A2 plus separate 24 V / 0 V semiconductor-output supply
Output supply galvanically isolated from system supply
Plug-in screw or spring-loaded type
Terminal sets are separately selected accessories.
750008 / 751008
Inputs I8–I15
T0M20–T3M23; safe semiconductor outputs O0–O3
Configurable IM0–IM3; inputs I4–I7
Configurable IM16–IM19; supply connections
1005720-EN-06, page 10. Original front view with connection legend and device/version markings.
Connect the system supply at A1/A2 and the semiconductor-output supply at the separate 24 V / 0 V connections. The output supply remains necessary even if no safe outputs are used. Use the marked supply arrangement rather than treating the output terminal as an interchangeable system-power input.
Test-pulse wiring allows the configured system to detect shorts across input circuits. When assigned as test outputs, these terminals serve the input test arrangement rather than external actuator loads. The wiring and selected input functions form one circuit in the Configurator project.
PNOZmulti Configurator defines the input functions, safety logic, output behaviour and actual digital expansion arrangement. USB provides a direct project-transfer route; a backlit display, rotary control and LEDs support local status and fault diagnosis. Reserve the configured test-pulse outputs for input fault monitoring.
Project storage differs by device version. The 2023 technical catalogue requires a chip card on the earlier B0.1. The current 1005720-EN-06 manual covers version 3.3 onward and makes the chip card optional for project transfer. Use the matching device version in the Configurator project; this is not a separate order for an expansion module.
101.4 × 45 × 120 mm
Manufacturer technical-data dimensions.
220 g
Horizontal on DIN rail
IP20
IP54 control cabinet
0 to +60 °C
Forced cabinet convection from 55 °C.
−25 to +70 °C
2000 m
Not permitted
Project transfer via USB; chip-card use depends on device version
1005720-EN-06, page 24. Original dimensional drawing; retain the indicated orientation and terminal-dependent dimensions.
Choose screw terminal set 750008 or spring-loaded set 751008 for PNOZ m B0.1. Include the configured digital I/O or other supported modules for the selected base version, and retain terminators at unused expansion interfaces. Project-storage accessories follow the device version described above.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.