Pilz PNOZ X Safety Relays
Pilz PNOZ X electromechanical safety relays. The first selection covers all eight PNOZ X3 AC-supply variants, each with alternative 24 V DC supply, three instantaneous safety contacts and integrated screw terminals.
View productsSelect the exact relay function and supply reference
PNOZ X includes different standalone safety-relay types. This first batch is the PNOZ X3 supply family; input mode, reset logic, output loading and the AC order variant all matter.
Showing 1–8 of 8

Safety control
Pilz 774310 PNOZ X3 24 V AC / 24 V DC Safety Relay
774310
New Original
$277.33

Safety control
Pilz 774311 PNOZ X3 42 V AC / 24 V DC Safety Relay
774311
New Original
$282.19

Safety control
Pilz 774312 PNOZ X3 48 V AC / 24 V DC Safety Relay
774312
New Original
$537.06

Safety control
Pilz 774314 PNOZ X3 110 V AC / 24 V DC Safety Relay
774314
New Original
$266.43

Safety control
Pilz 774315 PNOZ X3 115 V AC / 24 V DC Safety Relay
774315
New Original
$378.00

Safety control
Pilz 774316 PNOZ X3 120 V AC / 24 V DC Safety Relay
774316
New Original
$283.76

Safety control
Pilz 774318 PNOZ X3 230 V AC / 24 V DC Safety Relay
774318
New Original
$261.51

Safety control
Pilz 774319 PNOZ X3 240 V AC / 24 V DC Safety Relay
774319
New Original
$360.65
Eight supply variants in the first selection
All first-batch units are PNOZ X3 with 45 mm housings and integrated screw terminals.
24, 42 and 48 V AC / 24 V DC
774310, 774311 and 774312. The AC reference differs; each also supports 24 V DC on the dedicated DC supply terminals.
110, 115 and 120 V AC / 24 V DC
774314, 774315 and 774316. These are individual AC voltage ratings rather than one wide-input model.
230 and 240 V AC / 24 V DC
774318 and 774319. Preserve the exact AC voltage and use the correct AC or DC terminal arrangement.
Match the safety circuit, not just the housing
The first-batch output arrangement is three N/O safety contacts, one N/C auxiliary and one semiconductor status signal.
- 01
Keep status outputs outside the safety path
13–14, 23–24 and 33–34 are the safety contacts. 41–42 and Y32 report state; they do not add two more safety outputs.
- 02
Choose reset behavior deliberately
Automatic start can activate the relay once the input closes. Monitored start uses a different reset arrangement; prevent unexpected machine restart through the external circuit.
- 03
Contact load and service life
Utilisation category, simultaneous contact loading, fuse protection and switching frequency affect the output design. Component PL/SIL data alone do not define the complete circuit safety level.