Pilz PNOZ X3 safety relay with integrated screw terminals

Pilz 774315 PNOZ X3 115 V AC / 24 V DC Safety Relay

774315

PNOZ X3 standalone safety relay with 115 V AC or alternative 24 V DC supply. Three instantaneous N/O safety contacts, one N/C auxiliary contact and one semiconductor status output; 45 mm housing with integrated screw terminals.

Availability
In Stock
Condition
New Original
SKU
774315
Lifecycle
Active
$378.00
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Pilz. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Supply selection, safety-contact functions and installation data for 774315.

Exact ordering configuration

Manufacturer order number

774315

Product type

PNOZ X3

AC supply option

115 V AC, 50–60 Hz

DC supply option

24 V DC, alternative dedicated terminals

Supply tolerance

−15% / +10%

AC power consumption

5 VA

DC power consumption

2.5 W

Input circuits

1- or 2-channel wiring

Start modes

Automatic or monitored

Instantaneous safety contacts

3 N/O: 13–14, 23–24, 33–34

Auxiliary contact

1 N/C: 41–42

Semiconductor status output

1: Y32, 24 V DC / 20 mA

AC and DC use different terminal groups

The 115 V AC rating applies to the AC supply terminals A1/A2. Alternative 24 V DC power uses B1/B2 and a SELV/PELV supply. These are alternative supply arrangements on separate terminal groups. Do not apply the AC voltage to B1/B2; with AC operation, B2 is connected to functional earth as shown in the manufacturer wiring.

PNOZ X3 internal block and terminal configuration

Pilz operating manual p.8. Identifies the relay paths and the common configuration used by this supply family.

PNOZ X3 internal block and terminal configuration

PNOZ X3 internal block and terminal configuration

Pilz operating manual p.8. Identifies the relay paths and the common configuration used by this supply family.

Safety outputs and status indications have different roles

Use 13–14, 23–24 and 33–34 as the safety contact paths. The normally closed 41–42 contact and Y32 semiconductor signal report state and are not safety outputs. When the input circuit opens, the N/O safety contacts open and the auxiliary contact changes state.

Manufacturer supply and input wiring

Pilz operating manual p.12. Select the AC or DC supply drawing and the intended single/dual-channel input arrangement.

Manufacturer supply and input wiring

Manufacturer supply and input wiring

Pilz operating manual p.12. Select the AC or DC supply drawing and the intended single/dual-channel input arrangement.

Manufacturer start and feedback arrangements

Pilz operating manual p.13. Automatic and monitored start use different terminal links and reset arrangements.

Manufacturer start and feedback arrangements

Manufacturer start and feedback arrangements

Pilz operating manual p.13. Automatic and monitored start use different terminal links and reset arrangements.

Automatic start can re-enable the outputs after a safeguard resets

With automatic start, closing the input circuit can activate the relay without a separate reset action. Prevent an unexpected machine restart through the external control circuit. With monitored start, use the documented reset sequence; do not copy the automatic-start bridge arrangement.

Monitor the external switching devices in the feedback loop

Use feedback contacts from the external contactors or relays in the documented start/feedback arrangement. Single-channel input wiring has no input-circuit redundancy; dual-channel wiring and short-circuit detection require their matching terminal configuration.

Keep the mode-specific links distinct

For automatic start, S33 and S34 must not be linked. For monitored start, S13 and S14 must not be linked. The factory link and input bridges must match the chosen circuit diagram rather than being carried over from another installation.

Safety-contact load conditions

AC1 resistive load

Up to 8 A at 240 V AC

DC1 resistive load

Up to 8 A at 24 V DC; maximum 200 W

AC15 safety contact

Up to 5 A at 230 V AC

DC13 safety contact

Up to 6 A at 24 V DC, 6 cycles/min

AC-supplied thermal current, 3 loaded contacts

6.5 A per contact under stated AC1/DC1 conditions

DC-supplied thermal current, 3 loaded contacts

7 A per contact under stated AC1/DC1 conditions

Load category and simultaneous loading both matter

The resistive current rating is not an unrestricted inductive-load rating. Apply the utilisation category, the number of loaded contacts, external contact fuse protection and switching-life curve together. Use suppression on inductive loads to limit contact wear.

Component safety data must be used with the actual circuit

The manual provides component data up to PL e / Category 4 and SIL CL 3. Input redundancy, feedback, switching demand and contact life remain part of the complete safety function. For the stated high-level use, the manual requires the contacts to be opened and the relay restarted at least monthly so diagnostics can check opening; lower-level SIL CL 2 / PL d use requires at least yearly operation.

Installed relay

Width × height × depth

45 × 87 × 121 mm

Terminals

Integrated screw terminals

Terminal tightening torque

0.6 N·m

Mounting

DIN rail; any mounting position

Operating ambient

−20 to +55 °C

Storage ambient

−40 to +85 °C

Housing protection

IP40

Terminal protection

IP20

Required mounting-area protection

IP54

Weight

375 g

Manufacturer outline dimensions

Pilz operating manual p.15. The outline drawing includes the overall depth and terminal profile.

Manufacturer outline dimensions

Manufacturer outline dimensions

Pilz operating manual p.15. The outline drawing includes the overall depth and terminal profile.

Match the order number as well as PNOZ X3

Order 774315 for the 115 V AC / 24 V DC supply arrangement. Other PNOZ X3 order numbers use different AC voltages; PNOZ X3P, X3.10P and other PNOZ X types are separate devices, not interchangeable spellings.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.