ABB MS116 Manual Motor Starters
ABB MS116 thermal-magnetic manual motor starters combine local ON/OFF switching with class 10A overload protection and magnetic short-circuit tripping. The first selection covers ten standard screw-terminal models with adjustment ranges from 0.10 to 10 A.
View productsSelect by motor current, fault level and starter arrangement
Choose a thermal range containing the motor rated current. Then match the supply voltage, available fault current and contactor combination. Thermal adjustment, magnetic pickup and short-circuit breaking capacity are separate specifications.
Showing 1–10 of 10

Motor control and switching
ABB MS116-0.16 0.10–0.16 A Manual Motor Starter
MS116-0.16
New Original
$45.46

Motor control and switching
ABB MS116-0.25 0.16–0.25 A Manual Motor Starter
MS116-0.25
New Original
$45.46

Motor control and switching
ABB MS116-0.4 0.25–0.40 A Manual Motor Starter
MS116-0.4
New Original
$212.26

Motor control and switching
ABB MS116-0.63 0.40–0.63 A Manual Motor Starter
MS116-0.63
New Original
$45.50

Motor control and switching
ABB MS116-1.0 0.63–1.00 A Manual Motor Starter
MS116-1.0
New Original
$178.99

Motor control and switching
ABB MS116-1.6 1.00–1.60 A Manual Motor Starter
MS116-1.6
New Original
$138.32

Motor control and switching
ABB MS116-10 6.30–10.0 A Manual Motor Starter
MS116-10
New Original
$120.76

Motor control and switching
ABB MS116-2.5 1.60–2.50 A Manual Motor Starter
MS116-2.5
New Original
$49.47

Motor control and switching
ABB MS116-4.0 2.50–4.00 A Manual Motor Starter
MS116-4.0
New Original
$178.99

Motor control and switching
ABB MS116-6.3 4.00–6.30 A Manual Motor Starter
MS116-6.3
New Original
$176.64
Ten current ranges in the compact MS116 frame
All selected models have three main poles, screw terminals, a local rotary handle and class 10A thermal overload protection.
0.10–1.00 A adjustment ranges
MS116-0.16, -0.25, -0.4, -0.63 and -1.0 provide five overlapping motor-current selections. Their magnetic settings differ from the adjustable thermal dial.
1.00–4.00 A adjustment ranges
MS116-1.6, -2.5 and -4.0 cover successive thermal ranges. The voltage-specific IEC fault ratings and UL/CSA contactor selection change across these models.
4.00–10.0 A adjustment ranges
MS116-6.3 and -10 complete the first selection. Genuine12/16/20/25/32A variants can be added to the same family later; MS132 and MS165 remain separate ranges.
Build the complete motor starter circuit
A manual motor starter, contactor and branch-circuit arrangement perform different jobs.
- 01
Use the motor rated current
The front dial sets thermal overload protection directly in amperes. The motor rated current must fall inside the selected model’s range; class10A does not mean a fixed10A device.
- 02
Match voltage and fault rating
Use the exact voltage row for Ics, Icu and conditional back-up fuses. A complete UL/CSA circuit’s rating is separate from IEC device breaking capacity and requires the stated branch-circuit protection.
- 03
Add remote switching with a contactor
MS116 supplies local manual switching. A separately controlled AF contactor adds remote switching; its coil voltage and tested coordination size must suit the circuit. Auxiliary contacts and connecting links are separate items.
- 04
Respect connection and ambient conditions
Selected models share a45mm-wide housing. Single-phase wiring uses all three protection poles. Open temperature-compensated, open operating and enclosed ambient limits are distinct.