MS116-0.16
Three-pole thermal-magnetic manual motor starter with 0.10–0.16 A adjustable overload protection, trip class 10A and 2 A instantaneous short-circuit setting. Screw terminals, rotary ON/OFF handle and 45 mm width. ABB order code 1SAM250000R1001.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of ABB. Brand names are used for identification and compatibility purposes only. Read disclaimer
Overload adjustment, fault protection and installation data for MS116-0.16 / 1SAM250000R1001.
MS116-0.16 switches a motor circuit manually and provides adjustable thermal overload protection, electromagnetic short-circuit tripping and phase-loss sensitivity. Select it when the motor’s rated current lies within 0.10–0.16 A. The rotary handle provides local ON/OFF operation; remote switching requires a separate contactor.
MS116-0.16
1SAM250000R1001
0.10–0.16 A
0.16 A
2 A
Separate magnetic setting; not the adjustable overload range.
10A
3
690 V AC
50/60 Hz
690 V
6 kV
1.7 W
The front scale is calibrated in amperes: set it to the motor’s rated current within 0.10–0.16 A. Do not multiply the nameplate current by the short-circuit trip factor or set the dial to 2 A. The thermal and magnetic mechanisms serve different faults. Trip class 10A describes the overload characteristic, not a fixed 10 A current rating.
Order 1SAM250000R1001 for this standard screw-terminal MS116-0.16. An MS116 supplied with preassembled HKF1-11 auxiliary contacts uses the different 1SAM250005R10xx order family. Auxiliary/signaling contacts, shunt trips and undervoltage releases are optional accessories.
| Parameter / condition | Ics (kA) | Icu (kA) | Maximum gG/aM back-up fuse |
|---|---|---|---|
| 230 V AC | 50 | 100 | — |
| 400 V AC | 50 | 100 | — |
| 440 V AC | 50 | 100 | — |
| 500 V AC | 30 | 100 | — |
| 690 V AC | 30 | 100 | — |
ABB datasheet Rev B, p.7. A dash means no back-up fuse is required up to the listed Icu. Fuse entries are maximum gG/aM ratings for short-circuit current up to 50 kA where Icc exceeds Ics; they are conditional ratings, not an unconditional 50 kA device rating.
At 400 V AC, this model has Ics = 50 kA and Icu = 100 kA in ABB’s IEC table. Ics is rated service short-circuit breaking capacity; Icu is rated ultimate capacity. These values are distinct from a complete UL/CSA starter combination’s short-circuit rating and from the 2 A magnetic trip setting.
AF09–AF16
30 kA
Motor disconnect / group installation; coordination Type 2
Separate listed fuse or UL489 / CSA C22.2 No.5 circuit breaker, sized to NEC/CEC
SA1 or SA3 adaptor
For the 480 V UL/CSA combination above, ABB lists AF09–AF16 contactors with MS116-0.16. Provide the listed branch-circuit protection and select the contactor coil supply independently of the motor voltage. Mechanical connecting links and additional auxiliary contacts are separate components. ABB’s coordination tool provides further tested combinations for other circuit arrangements.
Original ABB MS116 datasheet Rev B, p.2. The two single-phase arrangements route the load through all three protection poles; the three-phase diagram uses one pole per phase. Terminal numbers are shown in the lower diagram.
1L1, 3L2, 5L3
2T1, 4T2, 6T3
1 or 2 × 1–4 mm²
1 or 2 × 0.75–2.5 mm²
9 mm
0.8–1.2 N·m
Pozidriv 2
Follow one of the manufacturer’s illustrated single-phase loop arrangements so all three thermal elements carry the load current. Simply leaving a pole unused is not the shown single-phase arrangement and does not provide the intended phase-loss-sensitive operation.
The trip-free mechanism allows protective opening even if the handle is held in the ON position. The front test function supports checking the trip mechanism. A remote ON/OFF command is handled by a separately controlled contactor, not by the MS116 rotary handle.
Original ABB MS116 datasheet Rev B, p.4, dimensions in mm and inches. Applies to all ten selected models. FS116 screw fixing and the larger ≥20 A housing are separate drawings and are not shown here.
45 / 90 mm
TH35-7.5 or TH35-15 to IEC 60715
FS116 accessory kit
−25 to +55 °C
−25 to +70 °C
Distinct from the compensated range.
0 to +40 °C
−50 to +80 °C
2,000 m
IP20 / IP10
100,000 operations
100,000 operations
Horizontal 0 mm; vertical 150 mm
ABB lists group mounting separately as on request.
Horizontal 0 mm up to 400 V; >1.5 mm up to 690 V; vertical 75 mm
The −25 to +55 °C range is the documented temperature-compensated range. The open-device operating maximum is +70 °C, while an IB132 enclosure has a 0 to +40 °C rating. Plan the enclosure and current setting using the applicable condition rather than treating all three temperatures as one rating.
ABB specifies up to 15 operations per hour without early tripping, or 60 per hour at 40% duty ratio, when motor breaking current is 6 × In and starting time does not exceed 1 second. The separate 170 cycles/h maximum operating-frequency figure does not remove these motor-starting conditions.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.