Soft Starter vs VFD for Pumps, Fans and Conveyors

Choose a soft starter or VFD for a pump, fan or conveyor. Compare real ABB models, load behavior, starts per hour and the need for running-speed control.

  • Mason Alexander
  • Published Nov 27, 2026
  • 5 min read
ABB PSR3 soft starter with voltage ramp adjustments beside an ABB ACS580-01 variable frequency drive with a control panel.

Choose a soft starter when the motor will run at line speed and the problem is how it starts or stops. Choose a variable frequency drive (VFD) when the machine needs to change speed during production. A fixed-speed machine can still warrant a VFD when it needs more control of starting torque, repeatable acceleration or controlled braking. Begin with what the load has to do in each part of the cycle. 12

ABB PSR3 soft starter with voltage ramp adjustments beside an ABB ACS580-01 variable frequency drive with a control panel.
The ABB PSR3 at left illustrates the compact PSR controls. At right is an ACS580-01 drive family image. The article uses PSR12 and ACS580-01-07A3-4 data for the exact model comparisons.

What each device controls

A soft starter gradually raises the voltage applied to the motor while the supply frequency stays the same. Reducing voltage reduces the available starting torque as well as the current, so the load still needs enough torque to break away and accelerate. The ABB PSR12-600-70 controls two phases of a three-phase circuit and has an internal bypass. Once the bypass closes, the motor runs on the line supply. A soft-stop ramp can reduce applied voltage at shutdown, with the actual stopping behavior determined by the load. 123

A VFD changes the frequency and voltage it supplies to the motor. It can command a slower operating point, accelerate to another speed or follow a control signal during the run. The ABB ACS580-01-07A3-4 is a 400 V-class example with a 3 kW IEC nominal rating and a 7.2 A nominal output current. Its usable current depends on the duty rating. The PSR12 is rated 12 A for IEC in-line operation at normal-start conditions. Each number describes its own device and test conditions. 135

What the machine must doSoft starterVFD
Accelerate more gently, then run at line speedCheck available starting torque and whether the start duration and starts per hour fit the starterCan do the job when tighter control of the acceleration or start torque is needed
Hold pressure, flow or belt speed at different operating pointsRunning speed follows the line supply and motor slipAdjusts running speed to suit a command, recipe or process loop
Slow a pump at shutdownVoltage ramp may help in suitable pump systems. Verify the resulting pressure transientCan command deceleration. The pump and check valve still determine the hydraulic outcome
Stop a high-inertia or overhauling load on demandCheck the load’s natural deceleration and the starter’s specific stop functionsSize the drive and any braking arrangement for the required stop and regenerated energy

Fixed-speed pump with a hard stop

Consider a transfer pump that runs at full speed whenever the tank calls for water. Starting the motor more gently may reduce mechanical shock. If the existing problem is a pressure spike at shutdown, establish when it occurs relative to forward flow, pump deceleration and check-valve closure. The pipe and valve behavior determines whether a simple voltage soft stop will help. For frequent starts or a long acceleration, use the soft starter’s thermal duty data alongside the motor’s running current. 136

If the same plant needs to maintain header pressure as demand changes, the job becomes continuous regulation. A VFD can change pump speed in response to pressure feedback. Establish minimum usable flow, minimum operating speed and the required head with the pump supplier. An application with substantial static head can reach a point where further speed reduction gives little useful flow. 24

Variable-flow fan with a damper

A fan that spends hours pushing against a partly closed damper is a different case. Where the process allows it, reducing fan speed can supply the required airflow with less shaft power. On an ideal centrifugal load at comparable operating points, shaft power scales with the cube of speed. At 80% speed, the theoretical comparison is 0.8³ = 0.512, or about 51% of the original shaft power. An electrical energy estimate also needs the actual system curve, operating hours and efficiency of the fan, motor and drive. 4

ABB graph plotting power required against airflow for outlet damper, inlet guide vane, electric variable speed drive and theoretical power demand.
At a given airflow, ABB’s representative fan curves show how the choice of control method changes power demand. The grey line is the theoretical curve.

ABB’s comparison plots required power against airflow for several control methods. The green VSD curve and the grey theoretical curve differ even at the same airflow. Start with a representative operating day. Record the required airflow at full and reduced demand and how long the fan stays at each point. That gives the energy calculation a duty cycle. The motor nameplate kW alone gives little indication of how much time is spent at part load. 4

Loaded conveyor with frequent restarts

Ask whether the belt must accelerate empty, restart loaded after a stop or creep during production. A fixed-speed conveyor may suit a soft starter if the available breakaway torque and start duty work under the worst loaded condition. If the belt must synchronise with another machine, run at crawl speed or repeatedly restart loaded under tight acceleration limits, check a VFD’s torque performance, continuous and overload ratings, and motor cooling at low speed. A fast stop may add a separate braking requirement. 25

ABB’s PSR table shows why starts per hour belong in the equipment specification. For a 12 A motor and the table’s 40 °C conditions, 4 × Iₑ starting current and six-second ramp, the no-auxiliary-fan matrix shows PSR12 at 30 starts per hour and PSR16 at 40. The running current stays at 12 A in both cases. The thermal demand during acceleration changes which starter the table points to. 3

ABB PSR starts-per-hour matrix for use without an auxiliary fan, with the 12 A motor row outlined.
Read across the highlighted 12 A motor row. ABB shows PSR12 at 30 starts per hour and PSR16 at 40 for this table’s conditions, with no auxiliary fan.

Check the complete installation before choosing

For a soft starter, record main voltage, motor running current, starting current and time, starts per hour, control supply, bypass arrangement and external protection. On the PSR12-600-70, the main supply range and 100–240 V AC control supply are separate checks. For a VFD, record the motor winding connection, load profile, required speed range, braking duty, motor cable and control method. A change from line starting to a drive is also a change to the supply-side protection, motor circuit and command wiring. 135

For a fixed-speed comparison that includes DOL and star-delta, use the three-phase motor starter selection guide. If continuous speed control or the starting duty points to a drive, use the VFD sizing guide to compare the motor current with the drive’s light- or heavy-duty rating under the actual installation conditions.

References

  1. ABB Softstarter Catalog, PSR Compact Range

    ABB · 1SFC132012C0201 Rev K

  2. When to Use a Soft Starter or an AC Variable Frequency Drive