Exact product identification
Your quotation references the complete manufacturer part number to keep the requested product clear.

PSR12-600-70
PSR12-600-70 (1SFA896106R7000) is a compact, two-phase-controlled softstarter for three-phase motors: 12 A IEC, 5.5 kW at 400 V. It accepts 208–600 V AC main power and 100–240 V AC control power, with built-in bypass and adjustable voltage ramps. Motor protection is external.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of ABB. Brand names are used for identification and compatibility purposes only. Read disclaimer
Motor ratings, starting duty and installation for PSR12-600-70.
PSR12-600-70
1SFA896106R7000
12 A
11 A
Use the matching UL/CSA motor-power table.
208–600 V AC, +10% / −15%
50/60 Hz, ±5%
100–240 V AC, 50/60 Hz
This is the -70 AC-control version.
In-line, three phase
Two
Built in
| Parameter / condition | 230 V AC | 400 V AC | 500 V AC |
|---|---|---|---|
| Rated motor power | 3 kW | 5.5 kW | 5.5 kW |
| Parameter / condition | 200/208 V AC | 220/240 V AC | 440/480 V AC | 550/600 V AC |
|---|---|---|---|---|
| Rated motor power | 3 hp | 3 hp | 7.5 hp | 10 hp |
PSR12-600-70 is rated 12 A under IEC conditions and 11 A in the UL/CSA ordering table. Its 5.5 kW figure applies at 400 V, rather than across the entire voltage range. Select the motor from the table for its supply voltage, then account for starting duty, ambient temperature and altitude.
PSR progressively changes motor voltage during starting and stopping, then closes its internal bypass at full voltage. It does not provide variable-frequency speed control during normal running. The two controlled phases are part of a three-phase motor circuit; this is not a single-phase motor starter.
1–20 s
0–20 s
40–70%
Three front potentiometers
Available
Not fitted
A TOR LED indication is distinct from a separate relay output.
12 VA
6 A, slow acting
100–240 V control-supply version.
4.4 W
Current rev K catalog value, including the model-specific bypass behavior.
4 × Ie for 6 s
10
50% on / 50% off time.
20
Fan is optional; 50% on / 50% off time.
−25 to +60 °C
Above 40 °C: reduce current 0.8% per °C up to 60 °C
Up to 4000 m
Above 1000 m, apply the manufacturer altitude factor.
100 − (altitude in m − 1000) / 150, in percent
For altitudes above 1000 m up to 4000 m.
−40 to +70 °C
The 4 × Ie / 6 s starting duty and 50% on/off cycle underpin the standard duty figures. ABB also publishes a motor-current-versus-starts selection table at 40 °C; a smaller motor can allow more starts on a larger starter. A 100-start-per-hour family capability is not a blanket rating for every motor at this starter’s full current.
Built-in bypass reduces running losses but does not provide motor-overload or short-circuit protection. Use a coordinated manual motor starter, or the specified fuse/overload arrangement. A line contactor can provide upstream switching and open when an overload trips; it is separate from the internal bypass.
This size provides a RUN relay output. Its Run/TOR front LED also indicates ramping and full voltage, but it does not add the separate TOR relay terminal found on PSR25 and larger models.
ABB catalog rev K p.25, PSR3–PSR16 circuit group. Examples show MMS, MMS with an auxiliary contact, and fuses with contactor/overload protection. These show circuit functions; protective-device ratings and fault duty come from the coordination selection.
Connect the incoming three phases to 1L1, 3L2 and 5L3, with motor leads at 2T1, 4T2 and 6T3. A1/A2 receive the control supply and ST receives the start/stop command as shown in the applicable circuit. The main 208–600 V rating and the 100–240 V control-supply rating serve different terminals.
45 / 140 mm
114 mm
Use the complete dimension drawing for fixing centers and projections.
Screw or DIN-rail mounting
IP20
Install in a suitable equipment enclosure
Terminal protection is not a complete enclosed starter assembly.
ABB catalog rev K p.24, PSR3–PSR16 outline. Dimensions include mm and inch annotations, fixing centers and projections.
Mechanical connection kits join compatible ABB manual motor starters to the PSR. Fieldbus communication requires an external adapter and FieldbusPlug. These accessories are separate from the base softstarter and are selected for the actual frame and control system.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.