Skip to content
Yaskawa A1000 AC drive with LCD operator and Type 1 lower cover

Yaskawa CIMR-AU4A0031FAA A1000 380–480 V AC Drive

CIMR-AU4A0031FAA

A1000 vector AC drive with 380–480 V three-phase input and NEMA Type 1 enclosure. Rated 31 A in Normal Duty or 24 A in Heavy Duty, with a built-in braking transistor, LCD operator and RS-422/485 Modbus communication.

Availability
In Stock
Condition
New Original
SKU
CIMR-AU4A0031FAA
Lifecycle
Active
$4,377.73
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Yaskawa. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Duty selection, Type 1 installation and control wiring for CIMR-AU4A0031FAA.

Vector control for an industrial motor

CIMR-AU4A0031FAA is a US-region A1000 drive for a 380–480 V three-phase supply. It controls an induction or supported permanent-magnet motor using the selected V/f or vector method. Normal Duty and Heavy Duty are two operating ratings of this same order: 31 A ND or 24 A HD. Use HD when the load cycle needs the greater 60-second overload allowance.

Two duty ratings for the same drive

Two duty ratings for the same drive
Parameter / condition Normal Duty (ND)Heavy Duty (HD)
Rated output current31 A24 A
Overload for 60 seconds120% of rated output current150% of rated output current
Reference input current38 A29 A

Choose the motor nameplate current and overload cycle together. Input current values assume rated output and vary with supply impedance, transformer, reactor and wiring.

Supply and output limits

Input supply

380–480 V AC, three-phase, 50/60 Hz

Allowable input voltage fluctuation

−15% to +10%

Allowable input frequency fluctuation

±5%

Maximum output voltage

Three-phase, proportional to input voltage

Maximum output frequency

400 Hz, standard software

ND current rating condition

2 kHz carrier frequency

Higher carrier frequency requires output-current derating.

HD current rating condition

Up to 8 kHz carrier frequency

Higher carrier frequency requires output-current derating.

Braking transistor

Built in; external braking resistor optional

DC link choke

Separately selected option for this model

Enter motor data before tuning

Size the drive against motor nameplate current, peak torque and the acceleration/deceleration cycle. Select the motor type and control method, enter the nameplate data, then perform the appropriate Auto-Tuning procedure. Closed-loop operation needs the matching feedback option and encoder connection; a fieldbus or feedback card is not included merely because the drive supports it.

Exact FAA outline and environment

Enclosure

IP20 / NEMA Type 1

Width × height × depth

7.09 × 13.39 × 6.57 in

Complete FAA enclosure outline.

Manufacturer outline reference

DD.A1K.FR4.N1

Mounting

Vertical, heatsink against a closed surface

Operating ambient

−10 to +40 °C

Installed Type 1 condition.

Storage ambient

−20 to +60 °C

Humidity

95% RH maximum, non-condensing

Altitude without derating

1000 m maximum

Altitude with derating

Up to 3000 m

Single-drive and side-by-side spacing

Original Yaskawa America A1000 manual, p.55. Figure 2.2 gives the standard installation spacing. Figure 2.3 applies to a derated side-by-side installation with L8-35 set to 1.

Single-drive and side-by-side spacing

Single-drive and side-by-side spacing

Original Yaskawa America A1000 manual, p.55. Figure 2.2 gives the standard installation spacing. Figure 2.3 applies to a derated side-by-side installation with L8-35 set to 1.

Use the Type 1 ambient rating

The FAA order includes the Type 1 enclosure arrangement. Its +40 °C operating ceiling differs from the +50 °C open-type condition. Provide the illustrated airflow and wiring space. Side-by-side installation at the 2 mm minimum spacing requires derating and the L8-35 installation setting; it does not preserve every isolated-drive current rating.

Retain the full order code when replacing a drive

CIMR-AU4A0031FAA uses the FR4 NEMA Type 1 outline. Flange-mounted UAA and protected-chassis AAA orders have different mechanical arrangements. Leave room for the wiring duct, cover access and the required clearances in addition to the 7.09 × 13.39 × 6.57 in drive body.

A1000 standard connection diagram

Original US A1000 manual, p.113. Shared family diagram, example model 2A0040; select the 380–480 V three-phase supply for this 4A model. PG feedback, external motor fan, DC choke and braking resistor are optional/application-dependent equipment shown for context.

A1000 standard connection diagram

A1000 standard connection diagram

Original US A1000 manual, p.113. Shared family diagram, example model 2A0040; select the 380–480 V three-phase supply for this 4A model. PG feedback, external motor fan, DC choke and braking resistor are optional/application-dependent equipment shown for context.

Connection diagram conditions

Original US A1000 manual, p.114. These numbered notes belong to the preceding diagram, including sink/source links, analog signal settings and optional feedback equipment.

Connection diagram conditions

Connection diagram conditions

Original US A1000 manual, p.114. These numbered notes belong to the preceding diagram, including sink/source links, analog signal settings and optional feedback equipment.

Built-in control connections

Digital inputs

8 multifunction 24 V DC inputs

Analog inputs

3 multifunction inputs

Voltage/current/PTC selection depends on the terminal and switch setting.

Pulse input

1 multifunction input

Fault output

1 Form C relay

Multifunction relay outputs

3 Form A relays

Analog monitor outputs

2 multifunction outputs

Pulse monitor output

1 multifunction output

Standard communication

MEMOBUS/Modbus RTU over RS-422/485

Operator

LCD digital operator

Separate line, motor and DC terminals

Connect incoming AC to R/L1, S/L2 and T/L3; connect the motor to U/T1, V/T2 and W/T3. Bond protective earth and separate control wiring from power conductors. B1/B2 and the DC-link terminals are for the specified braking/DC options, not AC supply inputs. The internal braking transistor does not include an external resistor.

Select the signal mode in hardware and parameters

The S1–S8 digital inputs use the selected sink/source arrangement. The SC–SP link selects sink mode; SC–SN selects source mode; external input power uses its specified arrangement. Never short SP to SN. Set the A2 voltage/current switch, A3 analog/PTC selection and AM/FM output modes to match the attached circuits.

Add only the options the application uses

Industrial Ethernet and other fieldbus connections require the corresponding option card. Encoder feedback likewise needs the correct PG card for the feedback device. A DC link choke, braking resistor and input/output peripherals are separately selected. Safe Disable terminals are part of the safety control circuit; disabling torque does not disconnect the drive from the incoming mains.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.