Exact product identification
Your quotation references the complete manufacturer part number to keep the requested product clear.

CIMR-AU4A0005FAA
A1000 vector AC drive with 380–480 V three-phase input and NEMA Type 1 enclosure. Rated 5.4 A in Normal Duty or 4.8 A in Heavy Duty, with a built-in braking transistor, LCD operator and RS-422/485 Modbus communication.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Yaskawa. Brand names are used for identification and compatibility purposes only. Read disclaimer
Duty selection, Type 1 installation and control wiring for CIMR-AU4A0005FAA.
CIMR-AU4A0005FAA is a US-region A1000 drive for a 380–480 V three-phase supply. It controls an induction or supported permanent-magnet motor using the selected V/f or vector method. Normal Duty and Heavy Duty are two operating ratings of this same order: 5.4 A ND or 4.8 A HD. Use HD when the load cycle needs the greater 60-second overload allowance.
| Parameter / condition | Normal Duty (ND) | Heavy Duty (HD) |
|---|---|---|
| Rated output current | 5.4 A | 4.8 A |
| Overload for 60 seconds | 120% of rated output current | 150% of rated output current |
| Reference input current | 5.9 A | 4.4 A |
Choose the motor nameplate current and overload cycle together. Input current values assume rated output and vary with supply impedance, transformer, reactor and wiring.
380–480 V AC, three-phase, 50/60 Hz
−15% to +10%
±5%
Three-phase, proportional to input voltage
400 Hz, standard software
2 kHz carrier frequency
Higher carrier frequency requires output-current derating.
Up to 8 kHz carrier frequency
Higher carrier frequency requires output-current derating.
Built in; external braking resistor optional
Separately selected option for this model
Size the drive against motor nameplate current, peak torque and the acceleration/deceleration cycle. Select the motor type and control method, enter the nameplate data, then perform the appropriate Auto-Tuning procedure. Closed-loop operation needs the matching feedback option and encoder connection; a fieldbus or feedback card is not included merely because the drive supports it.
IP20 / NEMA Type 1
5.51 × 11.81 × 5.79 in
Complete FAA enclosure outline.
DD.A1K.FR1.N1
Vertical, heatsink against a closed surface
−10 to +40 °C
Installed Type 1 condition.
−20 to +60 °C
95% RH maximum, non-condensing
1000 m maximum
Up to 3000 m
Original Yaskawa America A1000 manual, p.55. Figure 2.2 gives the standard installation spacing. Figure 2.3 applies to a derated side-by-side installation with L8-35 set to 1.
The FAA order includes the Type 1 enclosure arrangement. Its +40 °C operating ceiling differs from the +50 °C open-type condition. Provide the illustrated airflow and wiring space. Side-by-side installation at the 2 mm minimum spacing requires derating and the L8-35 installation setting; it does not preserve every isolated-drive current rating.
CIMR-AU4A0005FAA uses the FR1 NEMA Type 1 outline. Flange-mounted UAA and protected-chassis AAA orders have different mechanical arrangements. Leave room for the wiring duct, cover access and the required clearances in addition to the 5.51 × 11.81 × 5.79 in drive body.
Original US A1000 manual, p.113. Shared family diagram, example model 2A0040; select the 380–480 V three-phase supply for this 4A model. PG feedback, external motor fan, DC choke and braking resistor are optional/application-dependent equipment shown for context.
Original US A1000 manual, p.114. These numbered notes belong to the preceding diagram, including sink/source links, analog signal settings and optional feedback equipment.
8 multifunction 24 V DC inputs
3 multifunction inputs
Voltage/current/PTC selection depends on the terminal and switch setting.
1 multifunction input
1 Form C relay
3 Form A relays
2 multifunction outputs
1 multifunction output
MEMOBUS/Modbus RTU over RS-422/485
LCD digital operator
Connect incoming AC to R/L1, S/L2 and T/L3; connect the motor to U/T1, V/T2 and W/T3. Bond protective earth and separate control wiring from power conductors. B1/B2 and the DC-link terminals are for the specified braking/DC options, not AC supply inputs. The internal braking transistor does not include an external resistor.
The S1–S8 digital inputs use the selected sink/source arrangement. The SC–SP link selects sink mode; SC–SN selects source mode; external input power uses its specified arrangement. Never short SP to SN. Set the A2 voltage/current switch, A3 analog/PTC selection and AM/FM output modes to match the attached circuits.
Industrial Ethernet and other fieldbus connections require the corresponding option card. Encoder feedback likewise needs the correct PG card for the feedback device. A DC link choke, braking resistor and input/output peripherals are separately selected. Safe Disable terminals are part of the safety control circuit; disabling torque does not disconnect the drive from the incoming mains.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.