Skip to content
Beckhoff EL4011 analog output terminal front view

Beckhoff EL4011 1-Channel 0–20 mA Analog Output Terminal

EL4011

1-channel EtherCAT analog output terminal for 0–20 mA control signals. 12-bit resolution, approximately 100 µs conversion time and 24 V DC output-stage supply via power contacts.

Availability
In Stock
Condition
New Original
SKU
EL4011
Lifecycle
Active
$299.00
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Beckhoff. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Output signal, load and terminal-station data for EL4011.

Send an analog setpoint to the process

EL4011 generates 1 0–20 mA current signal from EtherCAT output data. Use it to command equipment with a matching analog input, such as a drive reference or process actuator. It generates a control signal; it is not an analog measurement input or a power output for directly driving a motor.

Signal characteristics

Analog outputs

1

Nominal output range

0–20 mA

Resolution

12 bit

Ground reference

Single-ended; shared ground

Conversion time

Approximately 100 µs

Sampling type

Multiplex

Permitted load

<500 Ω

Error at 0 to +55 °C

<±0.1% of full-scale value

Error in extended temperature range

<±0.5% of full-scale value

Distributed Clocks

Supported

Process output data

1 × 16-bit analog output word

Keep total loop resistance within the output limit

The complete load presented to each output must remain below 500 Ω. Include the receiving input and series wiring resistance in the load budget. The nominal lower endpoint is 0 mA; this is distinct from a 4–20 mA output.

EL4011 terminal assignment and connection

Original Beckhoff EL40xx manual v4.6, p.28. The diagram shows exact signal terminals, ground and power contacts.

EL4011 terminal assignment and connection

EL4011 terminal assignment and connection

Original Beckhoff EL40xx manual v4.6, p.28. The diagram shows exact signal terminals, ground and power contacts.

E-bus and 24 V supply serve different functions

The E-bus supplies the terminal electronics; 24 V DC through the power contacts supplies the output stages. An operating EtherCAT connection alone does not provide the field output-stage supply. Route signal and return to the marked output/GND terminals.

Common ground is not per-channel isolation

Output channels share a common reference. The documented 500 V isolation is between E-bus and field voltage; it does not isolate every output channel from the others. Current-output channel ground is common with the 0 V DC supply.

Use only assigned terminal points

Follow the exact model drawing when changing channel density. Terminal points identified as without function are not spare connection points and must not be connected to conductors. Shield connections and signal returns have different roles.

Station requirements

Electronics supply

E-bus

Output-stage supply

24 V DC via power contacts

Typical E-bus current

140 mA

Typical 24 V power-contact current at full output

50 mA

Electrical isolation

500 V, E-bus/field voltage

Dimensions W × H × D

Approximately 15 × 100 × 70 mm

Aligned width

12 mm

Weight

Approximately 60 g

Operating ambient

−25 to +60 °C; current-output channel limits apply above +55 °C

Storage ambient

−40 to +85 °C

Humidity

95%, non-condensing

Protection rating

IP20

Mounting

35 mm DIN rail to EN 60715

Configure the exact terminal in the EtherCAT master

Install in an EtherCAT terminal row with a suitable coupler or controller, allocate E-bus and field power, and configure the exact output terminal in TwinCAT or the EtherCAT master. Its 16-bit output word is the process-data container for a 12-bit output, not a 16-bit analog-resolution claim.

Conversion time is one part of the control path

The approximately 100 µs conversion rating is terminal-specific. PLC task timing, EtherCAT cycle and the receiving device also affect command response. Distributed Clocks support provides a synchronization facility; it does not replace output conversion or application cycle planning.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.