SICK deTec4 Core Safety Light Curtains
SICK deTec4 Core safety light curtain components. The first batch covers separate senders and receivers at five protective heights, all with 14 mm resolution and 24 V DC supply.
View productsMatch height, resolution and component role
Ten single-component order codes cover 300, 450, 600, 750 and 900 mm nominal protective heights. Sender and receiver are separate order items; this catalog selection does not describe ten complete pair kits.
Showing 1–10 of 10

Safety control
SICK C4C-EA03010A10000 deTec4 Core 300 mm Receiver
C4C-EA03010A10000
New Original
$789.73

Safety control
SICK C4C-EA04510A10000 deTec4 Core 450 mm Receiver
C4C-EA04510A10000
New Original
$1,950.17

Safety control
SICK C4C-EA06010A10000 deTec4 Core 600 mm Receiver
C4C-EA06010A10000
New Original
$1,087.95

Safety control
SICK C4C-EA07510A10000 deTec4 Core 750 mm Receiver
C4C-EA07510A10000
New Original
$1,691.42

Safety control
SICK C4C-EA09010A10000 deTec4 Core 900 mm Receiver
C4C-EA09010A10000
New Original
$1,401.06

Safety control
SICK C4C-SA03010A10000 deTec4 Core 300 mm Sender
C4C-SA03010A10000
New Original
$903.27

Safety control
SICK C4C-SA04510A10000 deTec4 Core 450 mm Sender
C4C-SA04510A10000
New Original
$785.90

Safety control
SICK C4C-SA06010A10000 deTec4 Core 600 mm Sender
C4C-SA06010A10000
New Original
$910.59

Safety control
SICK C4C-SA07510A10000 deTec4 Core 750 mm Sender
C4C-SA07510A10000
New Original
$1,378.00

Safety control
SICK C4C-SA09010A10000 deTec4 Core 900 mm Sender
C4C-SA09010A10000
New Original
$1,245.02
Sender and receiver have distinct roles
Choose a matched 14 mm pair for the required protective height, then plan the safety control and physical guarding.
C4C-SA senders
Five light-emitting components, 300–900 mm nominal height. They use optical synchronization and separate power connections; the sender has no OSSD outputs.
C4C-EA receivers
Five corresponding receiving components with two monitored PNP OSSD outputs. Each requires the matching sender of the same Core version, height and resolution.
Select for the complete protective arrangement
Detection capability and installed geometry determine the appropriate matched components.
- 01
Protective field
14 mm detection capability is distinct from protective height and sender-to-receiver width. Match the selected field to the guarded opening.
- 02
Stopping-distance inputs
The selected 14 mm systems have height-dependent 11–14 ms response times. Include downstream control and machine stopping time in the separation-distance calculation.
- 03
OSSD and supply
Power each component from the specified SELV/PELV supply. Use both receiver OSSD channels and suitable downstream safety logic, including required restart and monitoring functions.