Phoenix Contact UNO POWER Second Generation Power Supplies
Phoenix Contact UNO2-designated second-generation UNO POWER supplies. The first selection covers seven 24 V DC models from30 to960 W: compact Push-in30–90 W and screw-connected120–960 W units.
View productsChoose output power and connection together
Match the control load, input voltage and cabinet space. The UNO2 first selection spans compact Push-in supplies and larger screw-connected units; legacy UNO-PS models and other product families remain separate.
Showing 1–7 of 7

Power supplies and circuit protection
Phoenix Contact 1096432 UNO2-PS/1AC/24DC/240W Power Supply
1096432
New Original
$193.49

Power supplies and circuit protection
Phoenix Contact 1110043 UNO2-PS/1AC/24DC/960W Power Supply
1110043
New Original
$274.51

Power supplies and circuit protection
Phoenix Contact 1110466 UNO2-PS/1AC/24DC/120W Power Supply
1110466
New Original
$66.02

Power supplies and circuit protection
Phoenix Contact 1399932 UNO2-PS/1AC/24DC/30W/PT Power Supply
1399932
New Original
$38.39

Power supplies and circuit protection
Phoenix Contact 1399933 UNO2-PS/1AC/24DC/60W/PT Power Supply
1399933
New Original
$44.55

Power supplies and circuit protection
Phoenix Contact 1399934 UNO2-PS/1AC/24DC/90W/PT Power Supply
1399934
New Original
$94.48

Power supplies and circuit protection
Phoenix Contact 2910105 UNO2-PS/1AC/24DC/480W Power Supply
2910105
New Original
$210.54
Seven 24 V power choices
Connection technology and input range distinguish the two groups.
30,60 and90 W with Push-in terminals
1399932/1399933/1399934.21/30/35 mm wide,90 mm high and deep.85–305 V AC operating input and adjustable24–29 V output.
120,240,480 and960 W with screw terminals
1110466/1096432/2910105/1110043.5/10/20/40 A at24 V nominal.35–126 mm wide,130 mm high,129 mm deep.85–264 V AC operating input; adjustable24–28 V output.
Size for cabinet conditions
A common nominal24 V output does not remove power, thermal or wiring differences.
- 01
Power remains the limiting budget
Output adjustment above24 V reduces the current available within the unit’s power class. Select startup and steady loads separately; do not infer a boost rating.
- 02
Temperature and convection
Operation spans−25 to+70 °C with2.5%/K output derating above+55 °C. Keep30 mm above and below for installation and airflow.
- 03
Order the complete reference
UNO2 identifies the selected generation. /PT marks Push-in connection; legacy UNO-PS, other voltages, UPS and redundancy components are separate references.