Mitsubishi Electric MELSEC iQ-F FX5UJ CPU Modules
Mitsubishi Electric FX5UJ compact PLC CPUs with Ethernet, USB and 48k-step flash program memory. The first batch covers all nine AC-powered 24/40/60-point configurations with relay, sink-transistor or source-transistor outputs.
View productsChoose physical I/O, output circuit and power budget
Match the field loads to relay or transistor outputs, then size the controller and expansion supply. This first selection covers the nine100–240 V AC configurations; genuine24 V DC versions remain within the same broader FX5UJ collection.
Showing 1–9 of 9

PLCs and control systems
Mitsubishi Electric FX5UJ-24MR/ES 24-Point FX5UJ PLC CPU
FX5UJ-24MR/ES
New Original
$671.00

PLCs and control systems
Mitsubishi Electric FX5UJ-24MT/ES 24-Point FX5UJ PLC CPU
FX5UJ-24MT/ES
New Original
$707.00

PLCs and control systems
Mitsubishi Electric FX5UJ-24MT/ESS 24-Point FX5UJ PLC CPU
FX5UJ-24MT/ESS
New Original
$671.00

PLCs and control systems
Mitsubishi Electric FX5UJ-40MR/ES 40-Point FX5UJ PLC CPU
FX5UJ-40MR/ES
New Original
$1,067.00

PLCs and control systems
Mitsubishi Electric FX5UJ-40MT/ES 40-Point FX5UJ PLC CPU
FX5UJ-40MT/ES
New Original
$1,067.00

PLCs and control systems
Mitsubishi Electric FX5UJ-40MT/ESS 40-Point FX5UJ PLC CPU
FX5UJ-40MT/ESS
New Original
$1,067.00

PLCs and control systems
Mitsubishi Electric FX5UJ-60MR/ES 60-Point FX5UJ PLC CPU
FX5UJ-60MR/ES
New Original
$1,257.00

PLCs and control systems
Mitsubishi Electric FX5UJ-60MT/ES 60-Point FX5UJ PLC CPU
FX5UJ-60MT/ES
New Original
$1,323.00

PLCs and control systems
Mitsubishi Electric FX5UJ-60MT/ESS 60-Point FX5UJ PLC CPU
FX5UJ-60MT/ESS
New Original
$1,323.00
Three I/O sizes, three output circuits
The selected nine CPUs share100–240 V AC supply, sink/source inputs, Ethernet and USB Mini-B.
MR/ES relay outputs
24/40/60-point models have14/24/36 inputs and10/16/24 relay outputs. Outputs switch external AC or DC circuits within the contact, common and thermal limits.
MT/ES sink transistor outputs
Matching physical I/O counts with DC sink outputs. The fast Y0–Y2 group supports pulse-positioning functions, subject to the specified channel and load conditions.
MT/ESS source transistor outputs
Matching physical I/O counts with DC source outputs and +V commons. /ESS changes the output circuit; these selected CPUs remain AC powered.
Plan the complete controller installation
Physical terminals, occupied addresses and available field-supply current are different quantities.
- 01
Count occupied system points
The24-point CPU occupies32points,40-point occupies40, and60-point occupies64. Local and remote I/O share a combined256point limit.
- 02
Budget every output common
Relay outputs are2A per point with6/8A common limits. Transistor outputs are0.5A per point with0.6/0.8A common limits. Temperature and simultaneous-ON conditions also apply.
- 03
Allocate service power and AC extensions
The service supply provides400mA when powering CPU inputs, or460/500/550mA with external input supply. Extension I/O consumes part of that budget. Keep powered extensions on the AC configuration route.
- 04
Check housing width and cooling space
24/40/60-point body widths are95/130/175mm, with90mm height and83mm depth. Allow50mm cooling clearance and apply the output-type-specific derating graph.