200 V-class Sigma-7 single-axis analog/pulse SERVOPACK, 0.1 kW maximum applicable motor capacity. 0.91 A rms continuous / 3.2 A rms instantaneous output; documented single- or three-phase main input, IP20, 40 mm-wide base-mounted frame.

Availability
In Stock
Available quantity
12 units
Condition
New Original
SKU
SGD7S-R90A00A
Lifecycle
Active
$589.00
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Yaskawa. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Motor capacity, analog/pulse integration and standard-frame installation for SGD7S-R90A00A.

100 W-class single-axis servo amplifier

SGD7S-R90A00A is a Sigma-7 SGD7S SERVOPACK with an analog-voltage/pulse-train reference interface and a maximum applicable motor capacity of 0.1 kW. It supplies 0.91 A rms continuously and 3.2 A rms instantaneously. The instantaneous value is not a continuous operating current or a fixed-duration overload allowance.

Ordering and output ratings

Manufacturer part number

SGD7S-R90A00A

Series / axis count

Sigma-7 SGD7S / single axis

Reference interface

Analog voltage / pulse train

Input voltage class

200 V AC

Maximum applicable motor capacity

0.1 kW

Continuous output current

0.91 A rms

Instantaneous maximum output current

3.2 A rms

Design revision

A, standard base model

Input phase changes the supply-side ratings

Input phase changes the supply-side ratings
Parameter / conditionThree-phase inputPermitted single-phase input
Main supply200–240 V AC, 50/60 Hz200–240 V AC, 50/60 Hz
Main input current at rated load0.8 A rms1.6 A rms
Supply capacity at rated load0.3 kVA0.3 kVA
Total power loss at rated load19 W19.1 W

Single-phase operation is documented for this R90A model and requires the main-circuit phase setting Pn00B = n.□1□□. Output current ratings remain 0.91 A rms continuous / 3.2 A rms instantaneous.

Control circuit supply

Control circuit power supply

200–240 V AC, single-phase, 50/60 Hz

Permitted supply voltage fluctuation

−15% to +10%

Applies to the stated main and control AC supply ratings.

Control input current at rated load

0.2 A rms

Match the motor and feedback as a system

Use a manufacturer-supported SERVOPACK/motor combination with matching voltage, encoder interface, continuous duty and peak demand. A motor with the same kW rating is not automatically a compatible servo axis. Motor power, encoder, brake and I/O cables are selected separately.

Analog or pulse commands, not a motion fieldbus

The 00 interface code identifies analog-voltage/pulse-train references. Use analog references for speed/torque control or pulse commands for position control with the appropriate mode and input settings. This base model does not have the MECHATROLINK, EtherCAT or PROFINET command interface of other SGD7S order codes.

Front-panel signal roles

CN1

Host I/O and command signals

Reference pulse input, reference voltage, sequence I/O and divided encoder pulse output.

CN2

Servomotor encoder / feedback

CN3

Digital Operator / RS-422A service communication

CN5

Analog monitor output

CN7

USB connection to a computer running SigmaWin+

CN8

Safety-function signal connection

Use SigmaWin+ for commissioning

SigmaWin+ connects through the service interface for parameter setup, monitoring and tuning. It does not turn USB into the machine’s real-time motion-command network. Keep command wiring, encoder feedback and motor power on their designated connections.

Base model and option modules are different deliverables

The standard A00A code does not specify a separately installed feedback, advanced-safety or controller option module. Those functions require the matching option and its own wiring/configuration; do not infer them from general Sigma-7 family marketing.

Regenerative resistor data

Built-in regenerative resistor

Not fitted

Minimum allowable external resistance

40 Ω

This is the minimum resistance limit, not the required resistor wattage for every machine.

No built-in resistor on this frame

The R90A frame has no built-in regenerative resistor. An application needing resistive energy dissipation uses an external resistor selected for its deceleration energy and duty cycle, with resistance no lower than 40 Ω. An external resistor is not included with this standard unit.

External resistor and brake are not interchangeable

The product manual gives the regeneration terminal arrangement for each frame. When replacing a built-in resistor with an external one, remove the specified B2–B3 link and connect the external resistor between B1/+ and B2 as directed for that model. Dynamic braking and a motor holding brake perform different stopping/holding roles; neither is a substitute for correctly sizing regenerative energy.

Standard base-mounted housing

Dimensions (W × H × D)

40 × 168 × 140 mm

Approximate mass

0.9 kg

Mounting

Base-mounted, upright on a vertical mounting surface

Mounting screws

2 × M4

Degree of protection

IP20

Surrounding air temperature

−5 to +55 °C

55–60 °C operation requires manufacturer derating.

Storage temperature

−20 to +85 °C

Relative humidity

≤95%, without freezing or condensation

Altitude

Up to 1,000 m

1,000–2,000 m requires manufacturer derating.

Housing and mounting dimensions

Original manufacturer drawing for the R90A standard base-mounted frame. Dimensions in millimetres; connected-cable space and mounting pitch are shown separately from body depth.

Housing and mounting dimensions

SGD7S R90A frame front, side and mounting-hole drawing, 40 × 168 × 140 mm body

Original manufacturer drawing for the R90A standard base-mounted frame. Dimensions in millimetres; connected-cable space and mounting pitch are shown separately from body depth.

Leave cable space and a cooling path

For an individually installed SERVOPACK, reserve at least 40 mm above/below and 30 mm on each side as shown in the manual. For grouped units, the documented right-side gap for this frame is 1 mm with at least 0.5 m/s fan airflow measured 10 mm above the top surface; grouping is not a blanket permission to eliminate ventilation. Connected cables need additional front clearance.

Install inside a suitable control cabinet

IP20 is the SERVOPACK enclosure rating, not an outdoor or washdown rating. Keep water, oil, conductive dust and corrosive gases away from the unit. The body dimensions exclude the connected-cable envelope shown in the original drawing.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.