J1000 V/f microdrive for 380–480 V three-phase input. 6.9 A Normal Duty / 5.5 A Heavy Duty output, with 4 HP ND and 3 HP HD motor ratings. Protected chassis, IP20, with keypad operation and built-in braking transistor.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Yaskawa. Brand names are used for identification and compatibility purposes only. Read disclaimer
Duty selection, control interfaces and installation envelope for CIMR-JU4A0007BAA.
CIMR-JU4A0007BAA is a J1000 microdrive for a 380–480 V three-phase supply and a three-phase AC induction motor. It uses open-loop V/f control for straightforward motor speed adjustment in conveyors, fans, pumps and compact machinery. The front LED keypad supports local parameter setting; remote commands can be assigned to the control terminals.
CIMR-JU4A0007BAA
J1000 / V/f control
380–480 V AC, three phase
−15% / +10% input voltage tolerance.
50 / 60 Hz, ±5%
6.9 A
4 HP
120% of rated current for 60 s
5.5 A
3 HP
150% of rated current for 60 s
0–400 Hz
Motor and mechanical limits still determine the usable speed range.
The 4 HP headline belongs to Normal Duty at 6.9 A. For a load requiring Heavy Duty overload capacity, this order is rated 3 HP and 5.5 A. This distinction matters when replacing a nominal 4 HP constant-torque installation.
The 4A order code identifies the 400 V-class three-phase input model. It is not a 200 V-class or single-phase input J1000. Select the motor connection for the applied output voltage and use the 5.5 A Heavy Duty or 6.9 A Normal Duty limit required by the load.
Front LED keypad, five-digit display
5
24 V logic; sink/source selection supported.
0–10 V DC or 4–20 mA
Select the corresponding input arrangement and parameters.
1 Form C relay
1 A at 250 V AC or 30 V DC.
0–10 V DC
8-step preset operation plus jog
Built-in braking transistor
External resistor selected separately.
Optional interface
RS-232C or RS-422/485 interfaces are separately selected options.
Use the keypad for local setup, or configure the digital inputs for machine run commands and the analog input for a remote speed reference. The monitor output and programmable relay provide separate feedback paths. A terminal assignment and the corresponding parameter selection are both needed for a working remote-control arrangement.
Serial networking is provided through an optional interface, rather than a built-in Ethernet or RS-485 terminal. The J1000 option list includes an RS-422/485 Modbus interface and an RS-232C remote interface. Choose the appropriate option and communication parameters for the host controller.
The internal braking transistor can switch an external dynamic-braking resistor. The resistor is not part of the bare drive order; resistance, braking power and duty cycle are separate selections. A rapid deceleration setting alone does not add regenerative energy capacity to the installation.
Protected chassis / IP20
5.00 × 4.25 × 6.06 in
Exact US mechanical table dimensions.
4.2 lb
Drive only; not shipping weight.
−10 to +50 °C
Protected-chassis installation.
−20 to +60 °C
Up to 95% RH, non-condensing
1000 m nominal
Higher-altitude operation requires output derating.
Panel mounting
DIN-rail attachment is a separately selected kit.
Optional kit
Not included in the BAA protected-chassis drive order.
Yaskawa DD.J1000.02 outline for this chassis group. H, W and D correspond to the inch dimensions in the table above. Overall depth and width vary by exact order; mounting-hole dimensions are in the manufacturer drawing resources.
This order requires 4.25 in of housing width and 6.06 in of depth before allowing for wiring access and installation clearances. The deeper chassis needs more enclosure depth than the lower-current 0001 and 0002 orders. IP20 protected chassis belongs inside an appropriate enclosure for the installation environment.
Use the complete CIMR-JU…BAA identity when matching an existing unit. Regional J1000 variants, voltage classes and enclosure arrangements can have different orders and options. Parameter transfer, control wiring and the chosen duty rating remain part of a drive replacement, even when the motor HP is unchanged.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.