Skip to content
Schneider Electric HMIST6200 Harmony ST6 black touchscreen and silver-edged bezel

Schneider Electric HMIST6200 Harmony ST6 4.3-inch Basic HMI

HMIST6200

Harmony ST6 Basic HMI with 4.3-inch 480 × 272 color resistive touchscreen, 1 Ethernet and 1 serial port, USB host/transfer and 24 V DC supply. 118.5 × 92.5 mm panel opening; EcoStruxure Operator Terminal Expert engineering.

Availability
In Stock
Available quantity
12 units
Condition
New Original
SKU
HMIST6200
Lifecycle
Active
$531.20
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Schneider Electric. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Display, communications, cabinet fit and operating requirements for HMIST6200.

4.3-inch Basic operator panel

HMIST6200 is a complete Harmony ST6 Basic HMI for machine visualization and operator input, with a 4.3-inch wide color display at 480 × 272 pixels. It runs an HMI project created with EcoStruxure Operator Terminal Expert and connects to the machine controller through one Ethernet port and one configurable serial port. This is the standard integrated Basic panel, rather than an STW6 web terminal or STM6 modular display.

Display and touch characteristics

Manufacturer part number

HMIST6200

Range / role

Harmony ST6 / Basic HMI

Actual display diagonal

4.3 inches, wide

Display technology

TFT color LCD

Display resolution

480 × 272 pixels

Display colors

16 million

Touch technology

Analog resistive, single touch

Brightness adjustment

16 levels

Backlight

White LED

Backlight service life

50,000 hours or more

Continuous operation at 25 °C, until brightness decreases to 25%.

Touch service life

1 million operations or more

Design the screen for single-touch operation

The resistive touch panel accepts one touch at a time. Two simultaneous touches can be interpreted at their midpoint, so screens should use deliberate single-touch controls rather than multi-finger gestures. The LCD pixel resolution describes the visible layout; it is separate from the touch sensor coordinate resolution.

Application hardware

Processor

ARM Cortex-A8

System memory

512 MB Flash EPROM

User data memory

128 MB

Backup memory

512 KB NVRAM

Listed application page count

200

Engineering software

EcoStruxure Operator Terminal Expert

Clock

Built-in real-time clock with primary battery backup

Transfer an HMI project to the panel

Create the screens, tags, alarms and controller connections in EcoStruxure Operator Terminal Expert, then transfer the project to the HMI. Schneider’s Basic-license compatibility FAQ includes all five standard HMIST6 models. The panel is not a general-purpose PC or a web-only browser terminal; the software license and engineering workstation are separate from this hardware order number.

Physical interfaces

Ethernet

1 × RJ45, 10BASE-T / 100BASE-TX

COM1

RJ45; RS-232C or RS-485, software selected

COM2

Not fitted

Normal serial speed

2,400–115,200 bit/s

MPI serial mode

Up to 187,500 bit/s

Via COM1 and the appropriate driver.

USB host

1 × USB 2.0 Type A; 5 V DC, 500 mA maximum

USB transfer connection

1 × USB 2.0 micro-B

USB cable distance

5 m maximum

Serial isolation

Serial interface is not isolated

Match the port function to the cable

HMIST6200 has two RJ45-shaped communication connectors with different functions: Ethernet and serial COM1. COM1 is selectable RS-232C/RS-485; it is not a second Ethernet socket. Its connector and pin assignment also differ from the D-Sub COM1 used on the larger ST6 panels.

COM1 RJ45 signal assignment

Pin 1

RD / RXD — RS-232C receive

Pin 2

SD / TXD — RS-232C transmit

Pins 4 / 5

D1 / D0 — RS-485 data

Pin 6

RS / RTS

Pin 8

Signal ground

Pins 3 / 7

No connection

Connector shell

Frame ground

Choose the driver and electrical interface together

The manufacturer lists Modbus, Uni-TE and third-party controller protocols. Select the exact controller driver, serial electrical mode or Ethernet connection in the HMI project, along with addressing and cable pinout. A manufacturer name in the supported-brand list does not make every controller or communication option interchangeable.

Keep external power connected during USB transfer

Power the HMI from its DC power connector before connecting the micro-B transfer cable to the engineering computer. USB is a transfer interface, not the panel’s operating power source. Remove the micro-B cable before normal communication with the machine controller, as directed by the user manual.

Cabinet fit

Overall body, W × H × D

134.5 × 108.5 × 43 mm

Panel opening, W × H

118.5 × 92.5 mm

Opening tolerance

+1 / −0 mm on width and height

Opening corner radius

Less than R3

Panel thickness with screw fasteners

1.6–5 mm

Weight

0.4 kg or less

Supplied installation fasteners

2

Fastener tightening torque

0.5 N·m

Installation clearance

At least 100 mm from adjacent structures/equipment

Maximum face inclination

30° from vertical

Original external dimensions

Original HMIST6200 data sheet, p.6. Body dimensions are not the panel cutout; the drawing includes the front bezel and projection.

HMIST6200 manufacturer front, left and bottom dimensional views with millimeter and inch labels

HMIST6200 manufacturer front, left and bottom dimensional views with millimeter and inch labels

Original HMIST6200 data sheet, p.6. Body dimensions are not the panel cutout; the drawing includes the front bezel and projection.

Use the cutout rather than the screen diagonal

The panel opening is 118.5 × 92.5 mm; the 134.5 × 108.5 mm front bezel overlaps that opening. The listed 43 mm body depth does not include connector bodies or cable bends. Leave the specified service and ventilation clearance behind and around the panel.

Protection applies to the installed front

The data sheet lists IP65 at the front and IP20 at the rear. The manual specifies IP65F and Type 1/4X/13 front protection when properly installed in a suitable enclosure, with Type 4X for indoor use. Fit the supplied gasket against a flat, rigid surface; the rear housing does not provide a complete machine enclosure.

Orient the power connector correctly

For portrait mounting, install the panel with its right side upward, placing the DC power connector at the top, and use a project layout that supports portrait operation. Keep ventilation slots clear and account for the cabinet’s internal temperature.

Supply and environment

Rated supply

24 V DC

Input voltage limits

19.2–28.8 V DC

Maximum power consumption

6.9 W

Maximum inrush current

30 A

Voltage-dip / short-interruption immunity

2 ms or less at rated voltage

DC connector terminals

+24 V / 0 V / FG

Power connector

XBTZGPWS1 type; supplied with panel

DC terminal tightening torque

0.56 N·m

Operating temperature

0–50 °C

Storage temperature

−20 to +60 °C

Relative humidity

10–90%, non-condensing

Wet-bulb temperature 39 °C or lower.

Operating altitude

2,000 m or lower

Cooling

Natural air circulation

Size the supply for startup and connected devices

The maximum 6.9 W consumption includes the panel’s permitted external-device loading; the 30 A inrush is a brief startup demand rather than steady current. Use an external SELV and limited-energy DC source, connect FG to ground, and include a means of disconnecting power because the HMI has no integral power switch.

Maintain the gasket and touch surface

Keep the unit indoors and out of direct sunlight. Clean the screen with a soft cloth, without pressing with a hard or pointed object. Inspect the installation gasket and replace it at least annually or sooner if damaged or dirty. The white LED backlight is not a user-replaceable lamp; the primary clock battery is a separate service item.

Standard Basic panel size comparison

Standard Basic panel size comparison
Parameter / conditionHMIST6200HMIST6400HMIST6500HMIST6600HMIST6700
Display diagonal4.3 in7 in10.1 in12.1 in15.6 in
LCD pixels480 × 272800 × 4801024 × 6001280 × 8001366 × 768
Ethernet / serial ports1 / 12 / 22 / 22 / 22 / 2
Panel opening, mm118.5 × 92.5190 × 135255 × 185295 × 217394 × 250

All five use 24 V DC and single-touch resistive panels. A larger display also needs a different cabinet opening and HMI project layout.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.