Exact product identification
Your quotation references the complete manufacturer part number to keep the requested product clear.

2967060
Complete PLC-INTERFACE screw-terminal relay module with 24 V DC input and two changeover contacts (DPDT). 14 mm wide, with a replaceable electromechanical relay and LED indication for DIN-rail control-signal interfacing.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Phoenix Contact. Brand names are used for identification and compatibility purposes only. Read disclaimer
Input drive, contact loads and DIN-rail wiring for PLC-RSC-24DC/21-21, article 2967060.
PLC-RSC-24DC/21-21 combines a screw-terminal base with a plugged electromechanical relay. Energizing A1/A2 transfers both changeover contacts together; removing the input returns them to the rest position. It provides galvanic separation between the driving circuit and switched load, with a input-status LED. Two contacts allow two separate load circuits to follow the same control signal.
2967060
PLC-RSC-24DC/21-21
24 V DC
20.2–33.6 V DC
18 mA
8 / 10 ms
0.43 W
Monostable; 100% operating factor
LED
Freewheel diode; polarized input
The driving circuit must supply 18 mA typically at the nominal 24 V DC input. A compatible voltage alone does not establish that a PLC output can drive the load: include the input current in the output-channel budget. Follow A1/A2 polarity and retain the complete PLC-RSC-24DC/21-21 order when replacing the module.
2 changeover contacts (DPDT)
AgNi
250 V AC/DC
6 A
Contact switching duty and ambient conditions impose separate limits.
15 A for 300 ms
5 V AC/DC at 10 mA
10 mA at 5 V
4 kV AC, 1 minute
Insulation test, not a working-voltage or switching rating.
| Parameter / condition | Maximum interrupting power |
|---|---|
| 24 V DC | 140 W |
| 48 V DC | 85 W |
| 60 V DC | 60 W |
| 110 V DC | 44 W |
| 220 V DC | 60 W |
| 250 V AC | 1500 VA |
Maximum ohmic-load power at each contact voltage. These values are not motor or solenoid utilization-category ratings, and do not turn the 6 A continuous-current limit into a 250 V DC breaking rating.
2 A at 24 V; 0.2 A at 250 V
3 A at 24 / 120 / 250 V
The 6 A continuous-current figure describes current carried by closed contacts. Use the interrupting-power table for resistive switching and the AC-15/DC-13 values for the corresponding control loads. These power-contact models are distinct from AU gold-contact signal variants and from solid-state PLC-INTERFACE modules.
Original Phoenix Contact 2967060 product data, p.7. A1/A2 is the input; 11/12/14 is common/NC/NO; 21/22/24 is the second common/NC/NO set. The diagram shows the unenergized contact state.
Connect the control input to A1/A2 and the load circuit through the numbered contacts. At rest, 11 connects to 12; when energized, 11 connects to 14. The second pole changes from 21–22 to 21–24 at the same time. The DC input includes suppression; connect the supply with the indicated polarity. The LED indicates input energization rather than independent proof of load continuity.
14 × 80 × 94 mm
NS 35/7.5 DIN rail
Screw terminals, M3
0.14–2.5 mm²
0.2–2.5 mm²
8 mm
0.6–0.8 Nm
IP20
−40 to +60 °C
Apply contact-load and thermal limits together.
−40 to +85 °C
Where the voltage between identical terminals of adjacent modules exceeds 250 V, such as different phase potentials, install the PLC-ATP separating plate. This separation does not raise the relay contact’s 250 V switching-voltage limit. Potential-bridging accessories are separate items; use them only within the intended circuit grouping.
Article 2967060 is the assembled module with its plugged relay. A bare PLC-BSC base or REL-MR replacement relay is a separate order. Preserve the input voltage, contact arrangement and screw-terminal connection when maintaining an existing panel. This is an ordinary electromechanical interface relay, not a dedicated safety relay.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.