Complete PLC-INTERFACE screw-terminal relay module with 12 V DC input and one changeover contact (SPDT). 6.2 mm wide, with a replaceable electromechanical relay and LED indication for DIN-rail control-signal interfacing.

Availability
In Stock
Condition
New Original
SKU
2966906
Lifecycle
Active
$26.24
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Phoenix Contact. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Input drive, contact loads and DIN-rail wiring for PLC-RSC-12DC/21, article 2966906.

A complete control-to-load interface

PLC-RSC-12DC/21 combines a screw-terminal base with a plugged electromechanical relay. Energizing A1/A2 transfers the changeover contact; removing the input returns it to the rest position. It provides galvanic separation between the driving circuit and switched load, with a input-status LED. One contact offers a common, normally closed and normally open terminal.

Input and response

Manufacturer article number

2966906

Manufacturer designation

PLC-RSC-12DC/21

Nominal module input

12 V DC

Input voltage range at 20 °C

9.72–16.8 V DC

Typical input current at nominal voltage

15.3 mA

Typical response / release time

5 / 8 ms

Maximum dissipation at nominal condition

0.18 W

Operating mode

Monostable; 100% operating factor

Input indication

LED

Input protection

Freewheel diode; polarized input

Match the driving output to the relay input

The driving circuit must supply 15.3 mA typically at the nominal 12 V DC input. A compatible voltage alone does not establish that a PLC output can drive the load: include the input current in the output-channel budget. Follow A1/A2 polarity and retain the complete PLC-RSC-12DC/21 order when replacing the module.

Output contact data

Contact arrangement

1 changeover contact (SPDT)

Contact material

AgSnO

Maximum switching voltage

250 V AC/DC

Limiting continuous current

6 A

Contact switching duty and ambient conditions impose separate limits.

Maximum inrush current

10 A for 4 s

Minimum switching voltage

5 V at 100 mA

Minimum switching current

10 mA at 12 V

Coil-to-contact test voltage

4 kV AC, 1 minute

Insulation test, not a working-voltage or switching rating.

Resistive-load interrupting ratings

Resistive-load interrupting ratings
Parameter / condition Maximum interrupting power
24 V DC140 W
48 V DC20 W
60 V DC18 W
110 V DC23 W
220 V DC40 W
250 V AC1500 VA

Maximum ohmic-load power at each contact voltage. These values are not motor or solenoid utilization-category ratings, and do not turn the 6 A continuous-current limit into a 250 V DC breaking rating.

Inductive control-load ratings

DC-13

2 A at 24 V; 0.2 A at 110 V; 0.1 A at 220 V

AC-15

3 A at 24 / 120 / 230 V

Choose by load voltage and duty

The 6 A continuous-current figure describes current carried by closed contacts. Use the interrupting-power table for resistive switching and the AC-15/DC-13 values for the corresponding control loads. These power-contact models are distinct from AU gold-contact signal variants and from solid-state PLC-INTERFACE modules.

Terminal and relay circuit

Original Phoenix Contact 2966906 product data, p.8. A1/A2 is the input; 11/12/14 is common/NC/NO. The diagram shows the unenergized contact state.

Terminal and relay circuit

Terminal and relay circuit

Original Phoenix Contact 2966906 product data, p.8. A1/A2 is the input; 11/12/14 is common/NC/NO. The diagram shows the unenergized contact state.

Keep the drive and load circuits separate

Connect the control input to A1/A2 and the load circuit through the numbered contacts. At rest, 11 connects to 12; when energized, 11 connects to 14. The DC input includes suppression; connect the supply with the indicated polarity. The LED indicates input energization rather than independent proof of load continuity.

Dimensions, terminals and environment

Width × height × depth

6.2 × 80 × 94 mm

Mounting

NS 35/7.5 DIN rail

Connection

Screw terminals, M3

Rigid / flexible conductor

0.14–2.5 mm²

Single ferrule conductor

0.2–2.5 mm²

Strip length

8 mm

Tightening torque

0.6–0.8 Nm

Relay-base protection

IP20

Operating ambient

−40 to +60 °C

Apply contact-load and thermal limits together.

Storage / transport ambient

−40 to +85 °C

Separate adjacent circuits at different potentials

Where the voltage between identical terminals of adjacent modules exceeds 250 V, such as different phase potentials, install the PLC-ATP separating plate. This separation does not raise the relay contact’s 250 V switching-voltage limit. Potential-bridging accessories are separate items; use them only within the intended circuit grouping.

Complete module versus replacement parts

Article 2966906 is the assembled module with its plugged relay. A bare PLC-BSC base or REL-MR replacement relay is a separate order. Preserve the input voltage, contact arrangement and screw-terminal connection when maintaining an existing panel. This is an ordinary electromechanical interface relay, not a dedicated safety relay.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.