S8VK-C 480 W DIN-rail power supply with 24 V DC, 20 A rated output. Single-phase 100–240 V AC input, adjustable output and screw terminals. DC input is supported with an additional 0.7 load factor; installation temperature and orientation also affect available current.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Omron. Brand names are used for identification and compatibility purposes only. Read disclaimer
Output capacity,input conditions and mounting for S8VK-C48024.
S8VK-C48024
480 W; 24 V DC; 20 A
100–240 V AC,single-phase
85–264 V AC
50/60 Hz
90–350 V DC
Apply the additional DC load factor.
−10% to +15%,guaranteed
21.6–27.6 V around the 24 V rating.
91%
4.8 / 2.4 A
130 mV
20 MHz bandwidth; ambient−25 to+60°C.
S8VK-C48024 provides 20 A at 24 V under its rated conditions. Add the steady loads and operating demand of the connected devices, then apply the input-voltage,temperature and mounting derating. The overload-protection threshold is not a continuous boost-current rating.
Set the output to the voltage required by the connected loads. The guaranteed adjustment range is−10% to+15%,but the adjuster can move above that range. Measure the actual output and keep it within every connected device’s permissible supply range.
Original Omron S8VK-C datasheet p.4. Curve A:standard vertical mounting;curve B:face-up. The same page identifies the model-specific input,PE and DC output positions. Apply the additional DC-input coefficients below the graph.
Derate 2.0% per °C above 40°C
Derate 1.67% per °C above 30°C
Derate2.5% per volt below 90 V
0.7
14.0 A
Apply this factor to the current permitted by the temperature/mounting curve.
At least 350 V DC; 12 A
105–160% of rated load current
Not supported
Up to two supplies with an external diode
Overload protection clears automatically when current returns to the rated range. Sustained short circuits or repeated load inrush can damage the supply; they are not normal operating duties. Overvoltage protection shuts the output off at approximately 130% of rated voltage. Remove its cause,then switch input off for at least three minutes before restoring power.
S8VK-C is not specified for parallel operation. Choose a supply with enough derated capacity for the load rather than directly tying two outputs together for current sharing. Series operation is a separate arrangement and requires the manufacturer’s external-diode circuit.
DIN rail;standard vertical or specified face-up orientation
95 / 125 mm
150 mm
Includes projections shown on the manufacturer drawing;do not substitute housing-only catalog depth.
1550 g
IP20
−25 to+60°C,with derating
−25 to+65°C
20–90% RH,non-condensing
Green DC ON LED
Original Omron datasheet p.7,dimensions in mm. Use the S8VK-C48024 section. Body dimensions,rail-stopper travel and projections are separately marked;leave installation and wiring space in addition to these outlines.
Connect AC input to L/N and protective earth to PE. The+V/−V terminals provide the 24 V DC output; repeated output terminals belong to the same output circuit,not independent power channels. For DC input,connect positive to L as specified by Omron. The internal L-side fuse is not user-replaceable and does not remove the external DC-fuse requirement.
Leave the manufacturer’s clearance for airflow and conductor access. Mounting direction changes the permitted load,so use the matching curve after laying out the cabinet. Front/side mounting brackets are separate accessories; select the size listed for this supply rather than treating them as standard included hardware.
The AC rating applies to the specified line source. Omron prohibits powering the supply from an inverter output,even at 50/60 Hz,because the waveform can increase internal heating. Line-to-line operation from a three-phase system is a different case:line voltage must stay within the permitted range and the N-side input requires the specified external protection.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.