Exact product identification
Your quotation references the complete manufacturer part number to keep the requested product clear.

NX1P2-9024DT
NX1P2 CPU with 14 digital inputs and 10 NPN transistor outputs, 0 motion-control servo axes plus four single-axis positioning axes. Built-in EtherCAT and EtherNet/IP; 24 V DC supply.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Omron. Brand names are used for identification and compatibility purposes only. Read disclaimer
Control capacity, NPN I/O wiring, network roles and cabinet requirements for NX1P2-9024DT.
NX1P2-9024DT combines 14 digital inputs and ten NPN transistor outputs with four single-axis positioning servo axes over EtherCAT. It has no motion-control servo axes: the four positioning axes do not provide the synchronized and coordinated motion functions of the 1040 or 1140 CPU variants.
NX1P2-9024DT
NX-series NX1P2 CPU Units
24 points
4
0
4
1.5 MB
32 kB
2 MB
2 ms
Sysmac Studio
Ladder Diagram, Structured Text and Function Blocks
| Parameter / condition | Motion-control servo axes | Single-axis positioning servo axes |
|---|---|---|
| Available on NX1P2-9024DT | 0 | 4 |
| Single-axis positioning | No motion-control axes on this CPU | Supported |
| Single-axis synchronized control | No motion-control axes on this CPU | Not supported |
| Single-axis torque control | No motion-control axes on this CPU | Not supported |
| Multi-axis coordinated control | No motion-control axes on this CPU | Not supported |
The 9024 models have no motion-control servo axes. The 1040 pair provides two; the 1140 pair provides four. All six provide four single-axis positioning axes.
DT selects NPN sinking outputs without built-in load short-circuit protection. Changing between DT and DT1 in the same 9024, 1040 or 1140 class changes the output circuit, not the motion-axis allocation. The 9024 CPU has one option-board slot; 1040 and 1140 CPUs have two.
14
24 V DC (15–28.8 V DC)
Supports NPN or PNP sensor wiring
00–13
2.5 µs max. ON and OFF
Configured input filtering adds delay.
15 V DC min.
5 V DC max. / 1 mA max.
Configured in groups of four points
10
NPN sinking
12–24 V DC (10.2–28.8 V DC)
300 mA
2.4 A
2.4 A per CPU
1 mA
0.1 mA max.
1.5 V max.
0.1 ms max.
0.8 ms max.
Not provided
The ten outputs share one common with a 2.4 A total load limit. Ten simultaneous 300 mA loads would total 3 A and exceed that limit; distribute load current within the 2.4 A common rating.
00–09
C0 (0V) to 0 V
Leave unconnected
+ / − for CPU supply, functional ground, input COM and numbered inputs
NPN output terminal assignment
Original Omron terminal layout for the 24-point NPN CPU variant. Follow the labeled common and return terminals; NC positions remain unconnected.
Connect output common C0 (0V) to the I/O supply return. The load connects between the positive I/O supply and the sinking output. DT outputs do not include load short-circuit protection. The CPU supply terminals are not an actuator service-supply output.
| Parameter / condition | EtherNet/IP port 1 | EtherCAT port 2 |
|---|---|---|
| Physical connector | One RJ45 | One RJ45 |
| Role | EtherNet/IP data exchange and Ethernet engineering connection | EtherCAT master for field I/O and drives |
| Physical layer | 10BASE-T / 100BASE-TX | 100BASE-TX |
| Maximum node-to-node cable length | 100 m through Ethernet switch | 100 m between EtherCAT nodes |
| Capacity | 32 cyclic tag-data-link connections | 16 EtherCAT slaves |
The two RJ45 connectors serve different network roles; a shared connector shape does not make them interchangeable.
Up to 8
Up to 24
Eight on the CPU rack plus sixteen on EtherCAT slave terminals.
2,000–8,000 µs in 250 µs increments
1
10 W maximum
0.8
Not supplied by the CPU
The CPU can supply up to 10 W of NX unit power for local module electronics. It does not supply NX-bus field I/O power. Local modules that receive field I/O power through the NX bus require an Additional I/O Power Supply Unit; that supply has a maximum 4 A I/O current. Add the local NX electronics load to the external CPU power budget.
NX1P2-9024DT has 1 option-board slot. NX1W-CIF01 adds RS-232C; NX1W-CIF11 adds RS-422A/485; NX1W-CIF12 adds isolated RS-422A/485. NX1W analog option boards provide the specified analog input/output functions. These interfaces are separately selected boards, not built-in serial or analog ports.
Select the complete NX1P2 order number, configure the built-in I/O and NX units, map EtherCAT slaves and allocate motion/positioning axes in the project. CPU unit version and project settings govern version-dependent functions; ring topology requires project unit version 1.40 or later and ring-capable slaves.
24 V DC (20.4–28.8 V DC)
6.70 W
Includes SD memory card and option board; excludes power supplied to NX units.
10 A max. for 0.1 ms max.; 2.5 A max. for 150 ms max.
4 A maximum
Non-isolated between CPU power input and internal circuit
Not provided
Not provided
130 × 100 × 71 mm
Includes NX-END02 end cover; excludes projecting parts.
590 g
Includes the end cover.
DIN rail inside a panel
0–55 °C
10–95% RH, no condensation
−25–70 °C
Excludes battery.
2,000 m
Free from corrosive gases
Less than 100 Ω
2 or less
II
24-point CPU front dimensions
Original Omron drawing shows the bare CPU width as 124 mm. The supplied NX-END02 end cover adds 6 mm, giving the 130 mm assembly width used above. Dimensions are in millimetres; projecting features are shown separately.
CPU side profile
Original Omron side-view dimensions in millimetres. Use the 71 mm overall depth and retain space for projecting parts and wiring.
One NX-END02 end cover is provided with the CPU unit. The CJ1W-BAT01 backup battery is sold separately. Install the end cover at the right end of the CPU/NX assembly; it is not an expansion I/O module. Select the SD card, option boards and external power supplies for the machine configuration.
Allow for the listed cold-start inrush and the local NX electronics power demand, in addition to the CPU consumption. Respect the 4 A supply-terminal through-current limit when daisy-chaining power wiring. External actuator loads need their own correctly wired I/O supply circuit.
Omron model information, family data and engineering documentation.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.