FR-D740-0.75K
FR-D740-0.75K is a standard FR-D700 inverter for three-phase 380–480 V supplies, with 2.2 A rated output and 0.75 kW maximum applicable motor capacity. V/F and magnetic-flux vector control, RS-485/Modbus RTU and a built-in braking transistor support compact machine applications.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Mitsubishi Electric. Brand names are used for identification and compatibility purposes only. Read disclaimer
Supply, motor and installation data for FR-D740-0.75K.
FR-D740-0.75K
FREQROL FR-D700, standard FR-D740
0.75 kW
For a Mitsubishi Electric four-pole standard motor.
2.2 A
1.7 kVA
Calculated at 440 V output.
Three-phase 380–480 V AC, 50/60 Hz
325–528 V AC
±5%
2.5 kVA
Depends on input impedance, including reactor and cable impedance.
Three-phase; maximum does not exceed input voltage
150% for 60 s; 200% for 0.5 s
Inverse-time characteristics; allow thermal recovery before repeated overload.
0.2–400 Hz
FR-D740-0.75K supplies 2.2 A continuously under its rated conditions. Its 0.75 kW motor figure is the manufacturer’s maximum applicable four-pole motor capacity, while the 1.7 kVA output figure uses a 440 V basis. Size the drive for the actual motor nameplate current and load rather than treating these three ratings as interchangeable.
V/F, general-purpose magnetic-flux vector control and optimum-excitation control are available. Starting torque of 150% or more at 1 Hz applies when magnetic-flux vector control and slip compensation are set. Enter the motor data and use the appropriate tuning and control settings for the connected motor.
The inverter includes a braking transistor, but the brake resistor is an external option. Connect the selected resistor at P/+ and PR and provide its thermal protection. High regenerative energy can require an external brake unit. The short-duration braking torque in the rating table is not a continuous regenerative-duty rating.
Five: STF, STR, RH, RM and RL
Functions assigned with Pr.178–Pr.182.
STF forward; STR reverse
Two: terminals 2 and 4
0–5 V or 0–10 V
4–20 mA, 0–5 V or 0–10 V
Match Pr.267 and the physical V/I switch; assign/enable AU for terminal 4 input.
Terminal 5
RUN and SO open-collector functions; A/B/C relay output
FM pulse-train output
RS-485, Mitsubishi inverter protocol and Modbus RTU
Integrated operation panel; optional FR-PU07 parameter unit
FR-D700 Applied manual, printed p.14 (PDF p.25). Original sink-logic diagram, analog input switch conditions, safety-stop terminals and optional braking connections. The single-phase inset belongs to other voltage classes; FR-D740 uses the three-phase main circuit.
Terminal 4 defaults to current input. A voltage reference requires the matching V/I switch position and Pr.267 setting; the AU input function must also be assigned and enabled to use terminal 4. Terminal 2 voltage selection is a separate setting. Keep analog common 5 distinct from digital contact common SD.
Use the PU connector for the specified parameter unit or serial communication connection. Its modular shape does not make it an Ethernet port. An RS-232 computer connection needs a suitable RS-232/RS-485 converter.
S1/S2 are the two safety-stop input channels, with SC as their common. Use them within the manufacturer’s specified safety circuit. Removing drive output through these inputs does not isolate the incoming mains or discharge the DC link; maintenance isolation is a separate function.
108 × 128 × 129.5 mm
1.3 kg
Natural cooling; no cooling fan
IP20, JEM1030
Vertical, on an enclosure mounting surface
At least 100 / 100 mm
At least 10 mm
Zero clearance between inverters permitted
Preserve the required top/bottom ventilation and wiring space.
−10 to +50 °C, non-freezing
Up to 90% RH, non-condensing
Up to 1000 m
−20 to +65 °C
Short-duration conditions such as transport.
Applied manual printed p.293 (PDF p.297), dimensions in mm. Use the FR-D740-0.75K row in the W/W1/D/D1 table; the fan exception applies to 0.4K and 0.75K.
Applied manual printed p.16 (PDF p.27), FR-D740-0.4K–3.7K group. Preserve the distinction between incoming R/L1,S/L2,T/L3 and motor U,V,W.
Connect the three-phase supply only to R/L1,S/L2 and T/L3, and the motor to U,V and W. Earth both drive and motor. Keep control wiring more than 10 cm from power wiring. For a DC reactor, remove the P/+–P1 jumper and connect the reactor there; P/+–PR is the separate brake-resistor circuit.
Mitsubishi Electric moved FR-D700 production to made-to-order on 1 July 2026 and states that production will continue for orders received by 31 January 2027. The listed successor for the standard 400 V class is the FR-D840 family. Its monitor and safety-common terminal arrangements differ, so a successor installation includes those wiring changes rather than a direct terminal-for-terminal swap.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.