EL9186
Passive EtherCAT terminal-row distribution module: 8 positive-potential points. Taps the matching side power-contact potentials. 12 mm aligned width; no process-data allocation.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Beckhoff. Brand names are used for identification and compatibility purposes only. Read disclaimer
Distribution topology and installation data for EL9186.
Eight terminal points connect internally to the positive power contact. Return conductors need a separate negative-potential distribution arrangement.
Original Beckhoff EL9xxx documentation v5.0.0, p.43. Lines and junctions show the internal conductive connections.
8 positive-potential points
Up to60 V DC /30 V AC
Up to10 A; respect the shared current path
500 V between E-bus and field voltage
0 bits
None
No
No
The10 A current-load rating is a shared-path constraint, not10 A available independently at every connected terminal point. Add the connected branch currents and size feed conductors and external protection for the complete distribution path. This passive terminal does not provide electronic overcurrent protection.
Approximately15 ×100 ×70 mm
12 mm
Approximately65 g
35 mm DIN rail to EN60715
−25 to+60 °C
−40 to+85 °C
95%, non-condensing
IP20
Standard terminal
Use the marked spring terminals and the exact internal diagram. Mechanical fit does not establish which points are joined internally. De-energize the distribution circuit before inserting, removing or changing conductors.
This model distributes the existing matching power-contact potential rather than creating a new supply segment. It does not provide a protective-earth distribution connection to the mounting rail. Use a separate infeed terminal when a new field-supply segment is required.
There are no switched inputs or outputs and no process-image bits to assign. Internal terminal connections determine the distribution behavior; there is no software channel configuration that can change the topology.
A terminal with the same number of connection points can have a different internal net arrangement. Match power-contact tapping versus independent nets, polarity and the applicable voltage limit before changing models.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.