Skip to content
ABB AF three-pole screw-terminal contactor

ABB AF26-30-00-13 3-Pole Contactor

AF26-30-00-13

Three-pole AF contactor with 100–250 V AC/DC electronic coil and screw terminals. 11 kW / 26 A at 380–400 V AC-3; no fitted auxiliary contacts.

Availability
In Stock
Condition
New Original
SKU
AF26-30-00-13
Lifecycle
Active

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of ABB. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Load selection, control circuit and installation data for AF26-30-00-13.

Switching three-phase motor and power circuits

The AF26-30-00-13 is a non-reversing contactor with three normally open main poles. Its 11 kW motor rating applies at 380–400 V AC in the AC-3 utilization category. The electronic control circuit accepts either AC or DC within its specified range.

Ordered configuration

Type

AF26-30-00-13

ABB order code

1SBL237001R1300

Main contacts

3 NO

Fitted auxiliary contacts

0 NO, 0 NC

AC-3 motor power, 380–400 V

11 kW

AC-3 operating current, 380–400 V

26 A; air close to contactor ≤60 °C

AC-1 operating current

45 A at ≤40 °C, Ue ≤690 V

Coil suffix

13

Control voltage

100–250 V AC, 50/60 Hz; 100–250 V DC

Use the rating for the actual load

AC-3 covers starting and switching running squirrel-cage motors; AC-1 describes non-inductive or slightly inductive loads. The AC-1 current is not a motor-current rating. Voltage, utilization category and temperature affect the permitted load, so a rating at 400 V does not transfer unchanged to 690 V.

Build a coordinated motor starter

A contactor switches the load; it does not provide motor overload or short-circuit protection. Combine it with the appropriate overload protection and upstream protective device. Select the tested coordination combination for the prospective fault current and motor duty.

One wide-range AC/DC coil

The -13 electronic coil is rated 100–250 V for both AC and DC operation. This is the control-circuit rating, separate from the main power circuit. Built-in surge suppression is part of the AF design.

Add feedback contacts when required

The -30-00 configuration has no fitted NO or NC auxiliary contacts. Add a suitable auxiliary block if the control scheme requires feedback, interlocking or a holding contact.

Use an appropriate control interface

These standard AF models are not the AF..Z versions designed for direct PLC-output control. Drive the 100–250 V coil through a control device rated for its voltage and switching duty.

Circuit roles

Coil terminals

A1 / A2

Main power paths

1L1–2T1, 3L2–4T2, 5L3–6T3

Standard body and main terminals

Width × height × depth

45 × 80 × 86 mm

Mounting

35 mm DIN rail

Main terminal style

Screw terminals with cable clamp

Main conductor stripping length

14 mm

Main terminal tightening torque

2.5 N·m

Coil terminal tightening torque

1.2 N·m

ABB dimensional drawing

Catalog 3/42; select the AF26 drawing. Dimensions are mm and inches. Allow additional space for accessories and conductors.

ABB dimensional drawing

ABB dimensional drawing

Catalog 3/42; select the AF26 drawing. Dimensions are mm and inches. Allow additional space for accessories and conductors.

ABB conductor and terminal data

Catalog 3/102. Use the AF26 column and the row for the actual conductor and ferrule. Main and coil terminals have different torque values.

ABB conductor and terminal data

ABB conductor and terminal data

Catalog 3/102. Use the AF26 column and the row for the actual conductor and ferrule. Main and coil terminals have different torque values.

Match conductor preparation to the terminal

Use the listed conductor cross-section for the cable type, number of conductors and ferrule arrangement. Tighten unused terminal screws as specified. Keep the main-power and control connections distinct; fitted accessories can change the installation envelope.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.