ABB AF 3-Pole Contactors
ABB standard AF three-pole contactors for motor control and power switching. The first batch covers ten AF09–AF80 screw-terminal references with 100–250 V AC/DC coils.
View productsMatch load duty, coil voltage and auxiliary contacts
The first ten non-reversing references share the -13 wide-range electronic coil. They differ in motor capacity, fitted auxiliaries, terminal size and mounting envelope. AFZ, four-pole and reversing assemblies are outside this collection.
Showing 1–10 of 10

Motor control and switching
ABB AF09-30-10-13 3-Pole Contactor
AF09-30-10-13
New Original
$44.03

Motor control and switching
ABB AF12-30-10-13 3-Pole Contactor
AF12-30-10-13
New Original
$51.74

Motor control and switching
ABB AF16-30-10-13 3-Pole Contactor
AF16-30-10-13
New Original
$68.84

Motor control and switching
ABB AF26-30-00-13 3-Pole Contactor
AF26-30-00-13
New Original
$92.19

Motor control and switching
ABB AF30-30-00-13 3-Pole Contactor
AF30-30-00-13
New Original
$133.59

Motor control and switching
ABB AF38-30-00-13 3-Pole Contactor
AF38-30-00-13
New Original
$202.52

Motor control and switching
ABB AF40-30-00-13 3-Pole Contactor
AF40-30-00-13
New Original
$204.73

Motor control and switching
ABB AF52-30-00-13 3-Pole Contactor
AF52-30-00-13
New Original
$252.22

Motor control and switching
ABB AF65-30-00-13 3-Pole Contactor
AF65-30-00-13
New Original
$313.50

Motor control and switching
ABB AF80-30-00-13 3-Pole Contactor
AF80-30-00-13
New Original
$448.97
Four frame groups in the first selection
All ten references have three normally open main poles and -13 electronic coils.
AF09, AF12 and AF16
4, 5.5 and 7.5 kW at 400 V AC-3. The selected -30-10 versions include one NO auxiliary contact and a 45 mm-wide body.
AF26, AF30 and AF38
11, 15 and 18.5 kW at 400 V AC-3. The selected -30-00 versions have no fitted auxiliaries; 45 mm-wide bodies with increased depth.
AF40, AF52, AF65 and AF80
18.5, 22, 30 and 37 kW at 400 V AC-3, no fitted auxiliaries in this batch. Larger terminal capacity and frame-specific dimensions support higher power circuits.
Select the complete switching arrangement
Motor power and main current are only part of contactor selection.
- 01
Load utilization category
Use the AC-3 motor rating at the actual voltage and temperature; do not substitute the higher AC-1 current. Provide coordinated overload and short-circuit protection.
- 02
100–250 V AC/DC coil
The -13 coil accepts AC at 50/60 Hz or DC within its rated range and includes surge suppression. Standard AF is distinct from PLC-oriented AF..Z variants.
- 03
Feedback and installation