Skip to content
Siemens SIMATIC ET 200SP DQ 4x24VDC/2A ST digital output module

Siemens ET 200SP DQ 4x24VDC/2A ST 6ES7132-6BD21-0BA0

6ES7132-6BD21-0BA0

Four-channel Standard 24 V DC PNP output module rated 2 A per channel. Provides substitute values and module-wise fault diagnostics, with temperature-dependent total-current limits.

Availability
In Stock
Available quantity
12 units
Condition
New Original
SKU
6ES7132-6BD21-0BA0
Lifecycle
Active
$61.99
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Siemens. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Output ratings, load limits and configuration for the DQ 4x24VDC/2A ST.

Four Standard outputs for 2 A loads

A four-channel Standard PNP output module for 24 V DC loads up to 2 A per channel. It provides configurable substitute values and module-wise wire-break and short-circuit diagnostics. The current 6BD21 generation requires its own engineering support.

Output electrical ratings

Digital outputs

4

Output logic

PNP, current-sourcing

Nominal output voltage

24 V DC

Rated current per channel

2 A

Maximum module output current

8 A

Subject to mounting orientation and ambient-temperature derating

Maximum lamp load per channel

10 W

Load resistance range

12 Ω to 3.4 kΩ

Residual current at signal 0, maximum

0.1 mA

Short-circuit protection

Electronic

Typical short-circuit response threshold

2.8–5.2 A

Output delay 0 → 1 / 1 → 0

50 / 100 µs, typical, resistive load

The protection threshold is not the rated load current

The 2 A channel rating is the usable load-current limit. The electronic short-circuit response threshold is a protection characteristic, not permission to operate a channel above its rated current. Fault diagnostics provide an additional troubleshooting function; they do not increase the channel rating.

Maximum total output current by mounting temperature

Maximum total output current by mounting temperature
Parameter / conditionHorizontal installationVertical installation
Up to +30 °C8 A8 A
Up to +40 °C8 A6 A
Up to +50 °C6 A4 A
Up to +60 °C4 ANot within rated vertical operating range

These are maximum module-total currents at the listed ambient-temperature limits, not a higher per-channel rating.

Switching limits

Resistive-load switching frequency, maximum

100 Hz

Inductive-load switching frequency

0.1 Hz

Higher rates depend on load current and the permitted switching-frequency curve in the module manual

Lamp-load switching frequency, maximum

10 Hz

Inductive shutdown-voltage limitation

Typically L+ − 50 V

Parallel outputs for increased current

Not permitted

Parallel outputs for redundant load control

Supported

Disable “Short circuit to L+” and “Wire break” diagnostics for the paired outputs to avoid false diagnostic messages

Size the load for its electrical behavior

Calculate the sum of the four actual channel currents using the mounting-temperature matrix. At +60 °C horizontal installation, the module total is limited to 4 A, so four channels cannot all carry 2 A. Inductive loads also have a switching-frequency limit; the 100 Hz resistive-load rating does not apply to solenoids.

Supply and electrical separation

Load supply L+

24 V DC

Permissible range: 19.2–28.8 V DC

Reverse polarity protection

Yes

Module current consumption, maximum

20 mA

Without load current

Typical power loss

1 W

Channel-to-channel isolation

No

Isolation from backplane bus

Yes

Shielded cable length, maximum

1000 m

Unshielded cable length, maximum

600 m

BaseUnit requirements by actuator wiring

BaseUnit requirements by actuator wiring
Parameter / conditionBaseUnit arrangement
1-wireBU type A0
2-wireBU type A0
3-wireBU type A0 with AUX terminals, or a potential distributor module

Start or continue the potential group

A light-colored BaseUnit starts a new potential group; a dark-colored BaseUnit continues the voltage buses from the module on its left. Select the module’s potential-group parameter to match the physical BaseUnit arrangement. The electronic module and BaseUnit are separate order items.

Terminal arrangement

Each channel has two output terminal positions: DQ0 at 1/5, DQ1 at 2/6, DQ2 at 3/7 and DQ3 at 4/8. These are connections to four output channels, not eight independent outputs.

Output circuit and terminal assignment

Schematic circuit diagram

04/2024 · A5E53132267-AA, Figure 4-1. Original output circuit, terminal mapping, supply and backplane-bus connections.

Schematic circuit diagram

Siemens DQ 4x24VDC/2A ST schematic circuit diagram with terminal markings and circuit legend

04/2024 · A5E53132267-AA, Figure 4-1. Original output circuit, terminal mapping, supply and backplane-bus connections.

Diagnostic capabilities

Supply voltage monitoring

Supported

Wire-break diagnostics

Module-wise

Short-circuit to M / L+ diagnostics

Module-wise

Dedicated channel fault LEDs

No

Substitute-value output

Supported

PWM / oversampling

Not supported

MSO

Not supported

Firmware update

Supported

Isochronous operation

Not supported

Address space

1 byte plus 1 byte for QI

Engineering system support

Engineering system support
Parameter / conditionSupported version / integration
STEP 7 TIA PortalV19 with HSP0425; integrated from V20
STEP 7 ClassicV5.5 SP3 with HSP0230 V11.0; integrated from V5.7 SP3
PROFINETGSDML V2.43
PROFIBUSSeparate GSD files, revisions 3 and 5 or later

Use the current 6BD21 module in the hardware catalog

TIA Portal V19 requires HSP0425; the module is integrated from V20. STEP 7 Classic support starts at V5.5 SP3 with HSP0230 V11.0. Do not treat the earlier 6BD20 configuration as this module’s catalog identity. Diagnostic messages are module-wise; there are no dedicated red channel fault LEDs.

Module dimensions and operating conditions

Dimensions W × H × D

15 × 73 × 58 mm

Electronic module; excludes BaseUnit and packaging

Approximate module weight

30 g

Horizontal operating temperature

−30 to +60 °C

Full stated range for this current module generation

Vertical operating temperature

−30 to +50 °C

Full stated range for this current module generation

Maximum installation altitude

5000 m

Above 2000 m, additional installation restrictions apply as described in the ET 200SP system manual

Color code

CC02

Mechanical coding

Type A

Packing unit

1 module

What this order number includes

6ES7132-6BD21-0BA0 identifies the DQ 4x24VDC/2A ST electronic module in a one-piece packing unit. Order the type A0 BaseUnit separately for the intended wiring arrangement. This current 6BD21 order number is not the older 6BD20 catalog number. It is not a fail-safe output module.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.