Skip to content
Schneider Electric Modicon M221 Book PNP Ethernet logic controller

Schneider Electric TM221ME32TK Modicon M221 32-I/O Book PNP Ethernet Controller

TM221ME32TK

A 32-point M221 Book Ethernet PLC with sixteen digital inputs and sixteen 0.1 A PNP outputs. HE10 connectors keep the controller narrow and support prewired cable or Advantys Telefast breakout arrangements.

Availability
In Stock
Available quantity
12 units
Condition
New Original
SKU
TM221ME32TK
Lifecycle
Active
$552.00
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Schneider Electric. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

I/O, PNP output wiring, communication and installation details for TM221ME32TK.

32-point Book Ethernet controller

The 32-point Book base doubles the digital channel count of the 16-point Book controller while retaining the narrow housing. Its HE10 connection system and 0.1 A outputs suit prewired signal circuits; it is not a sixteen-channel 0.5 A load controller.

Controller configuration

Manufacturer part number

TM221ME32TK

Brand

Schneider Electric

Product family

Modicon M221

Form factor

Book

Digital I/O total

32

Digital inputs plus digital outputs; analog inputs are additional

Digital inputs

16

Digital outputs

16

Analog inputs

2 × 0–10 V DC

Controller supply

24 V DC

20.4–28.8 V DC operating range

I/O connection

HE10 (MIL 20)

What distinguishes this model

The K suffix identifies HE10-connected I/O. A TWDFCW30K or TWDFCW50K free-wire cable, or a suitable Advantys Telefast interface, is a separate order item. The sixteen outputs are PNP and limited to 0.1 A each.

Digital signals and counting

There are 16 digital inputs in total, not 16 regular inputs plus four more. Four of those channels—I0, I1, I6 and I7—can be assigned to high-speed counting at up to 100 kHz. The remaining 12 channels are regular digital inputs. Choose the configured counting mode and input filter for the actual signal.

Input characteristics

Digital input circuit

24 V DC; IEC/EN 61131-2 Type 1; sink/source

Digital input voltage range

19.2–28.8 V DC

Fast input channels

I0, I1, I6, I7

Fast input cable

Shielded; maximum 10 m

Regular input cable

Unshielded; maximum 30 m

Analog channels

2 single-ended voltage inputs

Analog range

0–10 V DC

Analog resolution

10 bits

Analog input accuracy

±1% of full scale

Analog isolation

Not isolated from internal logic; negative poles connected internally

Analog connection

Dedicated supplied cables; 1 m

Voltage inputs are not 4–20 mA inputs

The two built-in analog channels accept 0–10 V voltage signals. Use an appropriate analog expansion module for current-loop measurement rather than treating the onboard connector as a native 4–20 mA input.

Connect the correct load circuit

Each PNP output is rated 0.1 A, with 1.6 A across Q0–Q15. Use these channels for signal-level loads or appropriate external interfaces, not the 0.5 A loads of the 16-point Book model. HE10 outputs require a suitable cable or breakout interface.

Output characteristics

Output circuit

PNP sourcing transistor

Total digital outputs

16

Rated current per output

0.1 A

Output voltage

24 V DC rated; 19.2–28.8 V DC range

Output current budget

1.6 A across Q0–Q15

Fast outputs

Q0 and Q1; up to 100 kHz

Short-circuit protection

Electronic protection

Regular output switching

Up to 100 Hz with resistive loads

Fast output functions

PLS / PWM / PTO / FREQGEN

Temperature and simultaneous loading

Transistor outputs derate with ambient temperature and output voltage. At 24 V DC, the hardware guide allows 100% simultaneous-on ratio through 40 °C, reducing to 80% at 55 °C. For pulse operation, use shielded output wiring no longer than 3 m.

Output connection diagram

TM221ME32TK output wiring

M221 hardware guide EIO0000003313.04, page 255. Free-wire cable arrangement with HE10 pin numbers and fast-output shielding.

TM221ME32TK output wiring

Official TM221ME32TK output wiring diagram with terminal labels and circuit legend

M221 hardware guide EIO0000003313.04, page 255. Free-wire cable arrangement with HE10 pin numbers and fast-output shielding.

Built-in interfaces

Ethernet

1 × RJ45; Modbus TCP/IP; 10/100 Mbit/s

Serial line

1 × RJ45; RS-232 / RS-485

Programming port

USB 2.0 Mini-B

Removable storage

SD card slot

RUN/STOP

Physical switch and configurable input control

Expansion architectures

Expansion architectures
Parameter / conditionConnection / equipmentSupported configuration
Local I/OTM3 or TM2 expansion busUp to 7 expansion modules
Remote I/OTM3 transmitter / receiver pairUp to 7 additional TM3 modules
Distributed I/OTM3 bus coupler over the appropriate networkSeparate bus-coupler configuration

The permitted configuration also depends on expansion-bus power consumption. TM3 transmitter/receiver modules do not count toward the seven expansion-I/O-module limit.

Book expansion uses the side bus

TM3 expansion attaches through the side expansion bus. The Book controller does not have the compact controller’s TMC2 cartridge slot. Expansion modules and communication accessories are separate order items.

Plan the HE10 breakout

The digital channels use HE10 connectors rather than individual screw terminals. TWDFCW30K and TWDFCW50K provide 3 m and 5 m free-wire cable options. Their general cable lengths do not override the 3 m shielded-cable limit for high-speed output use.

Program with Machine Expert – Basic

Use EcoStruxure Machine Expert – Basic for M221 application programming, hardware configuration and diagnostics. It is the Basic edition for this controller range, not the separate Machine Expert environment used for M241/M251 projects. USB Mini-B provides a local programming connection; this Ethernet model also has a network interface.

Application and data memory

Total RAM

512 kbytes

Application and data RAM

256 kbytes

Internal-variable RAM

256 kbytes

Nonvolatile application/data backup

256 kbytes

I/O expansion setup

Configured in Machine Expert – Basic

Installation conditions

Installation conditions
Parameter / conditionHorizontal mountingVertical mounting
Ambient operating temperature−10 to +55 °C−10 to +35 °C
Expansion-module positionBeside the controllerAbove the controller

Cabinet and environment

Protection

IP20 with protective covers fitted

Mounting

DIN rail or panel

Controller width

70 mm

Storage temperature

−25 to +70 °C

Relative humidity

10–95%; noncondensing

Operating altitude

0–2000 m

Installation environment

Pollution degree 2; enclosed industrial cabinet

Leave room for wiring and ventilation

Install the controller in an enclosure and maintain the mounting clearances in the hardware guide. Route power wiring separately from analog, communication and fast-I/O cables; shield the latter and terminate their shields at the grounding arrangement. M221 is a standard logic controller, not a safety controller.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.