Exact product identification
Your quotation references the complete manufacturer part number to keep the requested product clear.

TM221ME16T
A narrow M221 Book Ethernet PLC with eight digital inputs and eight PNP outputs, including two 100 kHz fast channels. Removable screw terminals and a 70 mm-wide housing suit compact 24 V DC machine cabinets.
Warranty coverage and terms are confirmed with your order.
We coordinate the fastest available shipping option for your destination.
Available payment methods are handled through secure payment channels.
Carrier and delivery options are confirmed for your destination before dispatch.
Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Schneider Electric. Brand names are used for identification and compatibility purposes only. Read disclaimer
I/O, PNP output wiring, communication and installation details for TM221ME16T.
The Book transistor controller keeps eight inputs and eight outputs in a 70 mm-wide housing. It combines six regular sourcing outputs with two fast channels, rather than the nine-input/seven-output split of a compact 16-point controller.
TM221ME16T
Schneider Electric
Modicon M221
Book
16
Digital inputs plus digital outputs; analog inputs are additional
8
8
2 × 0–10 V DC
24 V DC
20.4–28.8 V DC operating range
Removable screw terminal blocks
Book and compact controllers are distinct layouts: this model has 8 digital inputs and 8 outputs. The selected Book model has screw terminals; G-suffix spring-terminal versions are different order numbers.
There are 8 digital inputs in total, not 8 regular inputs plus four more. Four of those channels—I0, I1, I6 and I7—can be assigned to high-speed counting at up to 100 kHz. The remaining 4 channels are regular digital inputs. Choose the configured counting mode and input filter for the actual signal.
24 V DC; IEC/EN 61131-2 Type 1; sink/source
19.2–28.8 V DC
I0, I1, I6, I7
Shielded; maximum 10 m
Unshielded; maximum 30 m
2 single-ended voltage inputs
0–10 V DC
10 bits
±1% of full scale
Not isolated from internal logic; negative poles connected internally
Dedicated supplied cables; 1 m
The two built-in analog channels accept 0–10 V voltage signals. Use an appropriate analog expansion module for current-loop measurement rather than treating the onboard connector as a native 4–20 mA input.
These PNP outputs source current to 24 V DC loads. Apply the per-channel limit and the group-current budget together. Electronic short-circuit protection does not remove the need for correctly protected output power and wiring.
PNP sourcing transistor
8
0.5 A
24 V DC rated; 19.2–28.8 V DC range
3 A for the six regular outputs Q2–Q7; 4 A across all eight outputs
Q0 and Q1; up to 100 kHz
Electronic protection
Up to 100 Hz with resistive loads
PLS / PWM / PTO / FREQGEN
Transistor outputs derate with ambient temperature and output voltage. At 24 V DC, the hardware guide allows 100% simultaneous-on ratio through 40 °C, reducing to 80% at 55 °C. For pulse operation, use shielded output wiring no longer than 3 m.
TM221ME16T output wiring
M221 hardware guide EIO0000003313.04, page 228. Output supply terminals, load-current path and shielded wiring for Q0/Q1.
1 × RJ45; Modbus TCP/IP; 10/100 Mbit/s
1 × RJ45; RS-232 / RS-485
USB 2.0 Mini-B
SD card slot
Physical switch and configurable input control
| Parameter / condition | Connection / equipment | Supported configuration |
|---|---|---|
| Local I/O | TM3 or TM2 expansion bus | Up to 7 expansion modules |
| Remote I/O | TM3 transmitter / receiver pair | Up to 7 additional TM3 modules |
| Distributed I/O | TM3 bus coupler over the appropriate network | Separate bus-coupler configuration |
The permitted configuration also depends on expansion-bus power consumption. TM3 transmitter/receiver modules do not count toward the seven expansion-I/O-module limit.
TM3 expansion attaches through the side expansion bus. The Book controller does not have the compact controller’s TMC2 cartridge slot. Expansion modules and communication accessories are separate order items.
Use EcoStruxure Machine Expert – Basic for M221 application programming, hardware configuration and diagnostics. It is the Basic edition for this controller range, not the separate Machine Expert environment used for M241/M251 projects. USB Mini-B provides a local programming connection; this Ethernet model also has a network interface.
512 kbytes
256 kbytes
256 kbytes
256 kbytes
Configured in Machine Expert – Basic
| Parameter / condition | Horizontal mounting | Vertical mounting |
|---|---|---|
| Ambient operating temperature | −10 to +55 °C | −10 to +35 °C |
| Expansion-module position | Beside the controller | Above the controller |
IP20 with protective covers fitted
DIN rail or panel
70 mm
−25 to +70 °C
10–95%; noncondensing
0–2000 m
Pollution degree 2; enclosed industrial cabinet
Install the controller in an enclosure and maintain the mounting clearances in the hardware guide. Route power wiring separately from analog, communication and fast-I/O cables; shield the latter and terminate their shields at the grounding arrangement. M221 is a standard logic controller, not a safety controller.
Manufacturer resources for controller selection, wiring and programming.
Order the exact product and condition your project requires, with assistance from quotation through delivery.
Your quotation references the complete manufacturer part number to keep the requested product clear.
Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.
Shipping options are prepared around your destination, quantity and requested delivery date.
Access available manufacturer product data, manuals and certificates associated with the order number.