Skip to content
Honeywell XNX Universal Transmitter with yellow housing, round display and local controls

Honeywell XNX Universal Transmitter

XNX Universal Transmitter

Configurable fixed-gas transmitter for Honeywell EC, mV and IR detector interfaces. Standard 4–20 mA with HART, a local LCD and magnetic controls support industrial gas monitoring; housing, sensor personality and optional outputs define the configured unit.

Availability
In Stock
Available quantity
12 units
Condition
New Original
SKU
XNX Universal Transmitter
Lifecycle
Active
$1,141.98
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Honeywell. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Choose the sensor interface and fitted options first, then size the power and mounting arrangement for the complete assembly.

One transmitter interface for different sensing technologies

XNX brings local display, signal output and configuration controls to a range of fixed gas sensors. It is a configurable transmitter platform, not a standalone relay or a detector that measures every gas at once. The fitted sensor and personality board establish the gas-detection function.

Platform identity

Manufacturer

Honeywell

Product platform

XNX Universal Transmitter

Product role

Configurable transmitter for fixed gas detection

Sensor-interface choices

EC, mV or IR personality board

Standard control-system output

4–20 mA with HART

Local interface

Backlit multilingual LCD, status LEDs and magnetic switches

Select the personality for the sensor connection

Select the personality for the sensor connection
Parameter / conditionPersonalitySensor / detector examplesSelection consequence
ElectrochemicalECXNX toxic and oxygen electrochemical sensorsThe gas cartridge sets the target gas and measuring range.
MillivoltmVMPD catalytic or infrared cartridges; documented Sensepoint and Model 705 typesAn MPD infrared cartridge belongs to the mV personality, not the IR detector interface.
Infrared detector interfaceIRSearchpoint Optima Plus; Searchline Excel; documented generic 4–20 mA inputUsed with the external detector interface rather than an XNX EC cartridge.

The sensor sets gas range and response

Toxic gas concentration, oxygen volume, flammable-gas %LEL and open-path measurement are different sensing applications. Select a sensor and range for the gas hazard; the transmitter housing alone does not define a gas range, response time or measurement accuracy.

Supply voltage by input personality

Nominal supply

24 V DC

EC and mV input range

16–32 V DC

Required at the transmitter terminals.

IR input range

18–32 V DC

Required at the transmitter terminals.

Standard analog output

4–20 mA with HART

Source, sink or isolated arrangement selected at the POD switches.

Maximum power for documented assemblies

Maximum power for documented assemblies
Parameter / conditionAssemblyMaximum power
EC toxic sensorXNX EC (toxic)6.2 W
MPD sensorXNX mV with catalytic or IR cell6.5 W
Point infrared detectorXNX IR with Searchpoint Optima Plus9.7 W
Open-path receiverXNX IR with Searchline Excel receiver13.2 W

Size the circuit for the complete sensing assembly

Detector load and cable voltage drop determine the supply and cable selection. The Searchline Excel receiver value above is not a power budget for both ends of the open-path system. Terminal voltage limits apply after the voltage drop along the installed cable.

Fitted output options

Standard interface

4–20 mA and HART

Relay option

Two alarm relays and one fault relay

Modbus option

Isolated RS-485, Modbus RTU

Fieldbus option

FOUNDATION Fieldbus H1

Option-module combinations

Relay, Modbus and FOUNDATION Fieldbus options are mutually exclusive

Local HART port

Optional externally accessible connection

HART over the standard 4–20 mA loop does not mean the local port is fitted.

Do not confuse input communications with the site output

An IR personality’s detector-side interface and an optional Modbus output to the site controller serve different connections. Choose the control-system output independently of the sensor personality; a generic XNX name does not establish that a relay or bus option is installed.

Enclosure choices

Housing materials

Marine-finish aluminum alloy or 316 stainless steel

Approximate transmitter mass

2.8 kg aluminum / 5 kg stainless steel

Sensor and accessory assemblies add their own dimensions and weight.

Entry arrangement

Five cable/conduit/sensor entries

Entry threads

M25 or ¾-inch NPT

The approval/entry combination is selected in the complete order code.

Mounting

Integral surface-mount lugs; optional pipe or ceiling brackets

Enclosure protection

IP66 / NEMA 4X

Transmitter operating temperature

−40 to +65 °C

The selected sensor may have a narrower temperature range.

Manufacturer outline drawings for local sensor assemblies

Original XNX data-sheet page 5, with MPD, EC toxic/oxygen and Sensepoint PPM assemblies. Dimensions are in millimetres; aluminum outlines are shown. Stainless steel body dimensions differ slightly but mounting-hole locations are unchanged.

Manufacturer outline drawings for local sensor assemblies

Honeywell original XNX assembly dimension drawings showing MPD, EC and Sensepoint PPM mounting envelopes

Original XNX data-sheet page 5, with MPD, EC toxic/oxygen and Sensepoint PPM assemblies. Dimensions are in millimetres; aluminum outlines are shown. Stainless steel body dimensions differ slightly but mounting-hole locations are unchanged.

Allow for the fitted sensor and service access

The integral mounting pitch is shown separately from the sensor assembly envelope. An MPD assembly and an EC assembly have different overall heights, while a remotely mounted detector uses a different cable and mounting arrangement. Leave room to access the cover, cable entries and sensing element.

Match the installed approval and cable-entry system

Select the approval, thread system and suitable glands or conduit as one installation configuration. IP66 is an ingress rating; it does not replace the hazardous-area approval or the gas sensor’s environmental limits.

The XNX name identifies the platform

A complete XNX order code specifies approval, entry thread, material, personality, output option, local HART port and sensor content. For a replacement, the full code and installed sensor identity distinguish a compatible configuration from a similar-looking housing.

Manufacturer ordering example: XNX-AMSV-NNCB1

Approval code A

ATEX/IEC

Entry code M

M25

Material code S

316 stainless steel

Personality code V

mV sensor interface

First N after the hyphen

No optional output module

Second N

No local HART port

Sensor code CB1

MPD catalytic sensor, 0–100% LEL

Standard output retained

4–20 mA with HART

Configured example, not a universal package

XNX-AMSV-NNCB1 is the manufacturer’s example of a complete configured transmitter. An EC, IR, aluminum, relay-equipped or transmitter-only configuration uses a different order code. The example does not define the contents of every XNX shipment.

Sensors and accessories follow the order configuration

The standard transmitter supply includes integral mounting lugs, a magnetic wand/screwdriver, an Allen key and three blanking plugs. MPD or XNX EC sensors and cartridges are fitted when ordered; other detector equipment is supplied separately. Pipe and ceiling brackets, remote sensor kits and output-module options are separate selections.

Local configuration without opening the display cover

Magnetic switches operate the local display menus. Sensor zero/span calibration and functional testing use the selected sensor’s gas and range; changing a transmitter setting does not substitute for installing the correct sensing element.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.

Request an XNX transmitter configuration

Send the full order code or an existing nameplate for replacement sourcing. For a new installation, include the target gas and range, required output, housing/approval, quantity and destination.

Request an XNX quote