Skip to content
Honeywell XNX transmitter body with round LCD, magnetic controls and mounting lugs

Honeywell XNX-AMAE-NNNNN XNX EC Transmitter

XNX-AMAE-NNNNN

ATEX/IEC XNX EC transmitter, aluminum alloy, M25 entries, 16–32 V DC. EC barrier/adapter; gas cartridge selected separately. 4–20 mA with HART.

Availability
In Stock
Available quantity
12 units
Condition
New Original
SKU
XNX-AMAE-NNNNN
Lifecycle
Active
$1,983.60
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Honeywell. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Configuration, sensor-system integration and installation data for XNX-AMAE-NNNNN.

Aluminum, ATEX/IEC, M25

XNX-AMAE-NNNNN is a complete configured Honeywell XNX transmitter order code: aluminum alloy housing, ATEX/IEC approval selection, M25 entries and EC toxic/oxygen sensor interface. The standard 4–20 mA/HART configuration has no optional output module or local HART port.

Exact order-code interpretation

Manufacturer part number

XNX-AMAE-NNNNN

Approval

ATEX/IEC

Entry thread

M25

Housing

Aluminum alloy

Sensor personality

EC

Output option

N — no optional output module

Local HART port

N — not fitted

Sensor / range suffix

NNN — none specified

Use the full code for a replacement

M25 threads, ATEX/IEC approval selection and the EC input personality are part of this product’s identity. The aluminum housing is approximately 2.8 kg before separately selected sensing equipment. A different personality, entry thread or fitted option changes the ordered configuration.

An electrochemical transmitter interface, with the gas selected separately

XNX-AMAE-NNNNN provides the XNX EC interface for toxic-gas and oxygen electrochemical sensors. It includes the EC interface’s intrinsically safe barrier and adapter, but its NNN sensor/range suffix does not specify a gas cartridge. Select the matching XNX EC sensing components for the target gas and measuring range.

EC interface and sensing content

Personality

EC — electrochemical

Documented sensor family

XNX toxic and oxygen electrochemical sensors

EC interface hardware

Intrinsically safe barrier and adapter

Gas cartridge / measuring range

Not specified by this NNN order code

MPD catalytic or infrared sensor

Not the sensor interface of this EC configuration

Choose the cartridge by the hazard

Oxygen, hydrogen sulfide, carbon monoxide and other supported electrochemical applications use distinct sensor cartridges and ranges. Changing a display setting does not convert an EC cartridge to a different gas. A transmitter-only EC configuration is not a complete calibrated gas detector.

Include the selected sensor in the power budget

The manufacturer specifies 6.2 W maximum for an XNX EC toxic-sensor assembly. Use the selected sensor and the installed cable length when sizing supply capacity and voltage drop; this reference does not establish one universal measuring range or sensor response time.

Electrical integration

Nominal supply

24 V DC

Permissible terminal supply

16–32 V DC

Standard signal output

4–20 mA with HART

Current-loop topology

Selectable source, sink or isolated mode

Signal accuracy

±1% of full scale

Current output accuracy, not gas-sensor measurement accuracy.

Terminal conductors

0.5–2.5 mm²

Cage-style plug-in terminals with retaining screws.

Local controls

Magnetic switches; multilingual backlit LCD

Status indication

Alarm, power and fault LEDs

Supply voltage is required at the transmitter

Account for the connected detector, cable resistance and controller input when choosing the supply and cable. Source/sink/isolated switches are on the rear of the POD; the wiring and current-loop load must match the selected arrangement.

No optional output module is installed

The N option code supplies standard 4–20 mA with HART, without relay, Modbus RTU or FOUNDATION Fieldbus output hardware. Those are other module configurations, not simultaneously available outputs of this exact order code.

HART on the loop; no separate local port

HART communication is available over the standard 4–20 mA signal. The local-HART code is N, so this unit does not include the optional externally accessible HART connection port.

Housing and mounting

Enclosure material

Aluminum alloy

Housing finish

Marine-grade coating

Approximate transmitter mass

2.8 kg

Transmitter housing reference; not a packed shipping weight or a complete remote detector system.

Housing entry paths

Five M25 entries

Sensor or local-HART hardware occupies an entry when fitted.

Mounting

Integral surface-mount lugs

Other mounting arrangements

Pipe or ceiling mounting with separately selected brackets

Enclosure protection

IP66 / NEMA 4X

Transmitter temperature range

−40 to +65 °C

The selected sensor/detector can impose a narrower operating range.

Transmitter body reference

Nominal body dimensions (H × W × D)

160 × 197 × 114 mm

Manufacturer transmitter-only reference; excludes separately selected detector/sensor assemblies.

Leave room for the sensing equipment and connections

The selected EC sensor adapter, sensing element and any weather protection add to the installed envelope. Use the assembly dimensions for the chosen sensor arrangement rather than treating the transmitter body as the complete detector.

Original transmitter construction

Manufacturer platform construction diagram. This EC configuration includes the EC sensor-interface barrier and adapter. The optional local HART interface shown is not fitted on this N-code model.

Original transmitter construction

Original Honeywell XNX construction diagram identifying the cover, POD, enclosure, mounting lugs and optional interfaces

Manufacturer platform construction diagram. This EC configuration includes the EC sensor-interface barrier and adapter. The optional local HART interface shown is not fitted on this N-code model.

Keep thread and approval selections together

XNX-AMAE-NNNNN uses M25 entries under its ATEX/IEC ordering selection. Use the corresponding certified glands/conduit and stopping plugs. The five housing entries are not five unused cable ports once a sensor or local interface has been fitted.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.