Beckhoff EL2088 digital output EtherCAT terminal

Beckhoff EL2088 8-Channel 0.5 A Digital Output EtherCAT Terminal

EL2088

8-channel 24 V DC EtherCAT digital-output terminal, 0.5 A per channel, ground switching with 3 A total limit. 1-wire EL spring terminals.

Availability
In Stock
Condition
New Original
SKU
EL2088
Lifecycle
Active
$115.00
Request a quote
Ask a product question

12 months warranty

Warranty coverage and terms are confirmed with your order.

Fast shipping

We coordinate the fastest available shipping option for your destination.

Secure payment

Available payment methods are handled through secure payment channels.

Worldwide delivery

Carrier and delivery options are confirmed for your destination before dispatch.

Independent supplier: Xindustra is not an authorized distributor, reseller, or representative of Beckhoff. Brand names are used for identification and compatibility purposes only. Read disclaimer

Technical specifications

Output characteristics, 1-wire terminal wiring, station power and control behavior for EL2088.

8 digital outputs for 24 V DC loads

EL2088 is an EL EtherCAT digital-output terminal rated 0.5 A per channel. Eight ground-switching outputs switch the load return to 0 V. This is the sinking-output choice, not the same load circuit as a positive-switching EL2008.

Output and load characteristics

Manufacturer part number

EL2088

Output polarity

Ground switching / sinking; switched 0 V

Number of outputs

8

Nominal voltage

24 V DC (-15%/+20%)

Max. output current

0.5 A (short-circuit proof) per channel, ∑ 3 A

Load type

resistive, inductive, lamp load

Reverse polarity protection

yes

Switching-off energy

< 100 mJ/channel

Switching times

typ. TON: 50 µs, typ. TOFF: 200 µs

Eight channels share a 3 A terminal limit

Each output is rated up to 0.5 A, but the terminal total is limited to 3 A. Eight simultaneous 0.5 A loads would exceed that limit. Allocate the combined load current within 3 A and connect the other side of each load to +24 V.

Separate station communication from field power

The terminal electronics use the E-bus; the 24 V DC actuator circuit uses the station power contacts. 1-wire describes the terminal connection arrangement, not an Ethernet cable or an external connector supplied with the terminal.

EL2088 terminal-point assignment

Terminal 1

Output 1

Output 1 (0 V)

Terminal 2

Output 3

Output 3 (0 V)

Terminal 3

Output 5

Output 5 (0 V)

Terminal 4

Output 7

Output 7 (0 V)

Terminal 5

Output 2

Output 2 (0 V)

Terminal 6

Output 4

Output 4 (0 V)

Terminal 7

Output 6

Output 6 (0 V)

Terminal 8

Output 8

Output 8 (0 V)

EL2088 terminals and output indicators

Original Beckhoff Information System terminal diagram. Match the numbered terminal points to the assignment table; load wiring differs between positive- and ground-switching models.

EL2088 terminals and output indicators

Beckhoff EL2088 terminal assignment and output LED diagram

Original Beckhoff Information System terminal diagram. Match the numbered terminal points to the assignment table; load wiring differs between positive- and ground-switching models.

Actuator supply and return routing

All eight connection points are switched 0 V outputs; they are not +24 V supply terminals. Provide the load’s +24 V feed separately.

Station power budget

Current consumption E-bus

typ. 110 mA

Current consumption power contacts

typ. 30 mA + load

Current load power contacts

Imax: 10 A

Electrical isolation

500 V (E-bus/field potential)

Power-contact capacity is not an output rating

The housing power contacts are rated to carry up to 10 A through the station segment. This does not increase a channel’s rated current or any model-specific total-current limit. Add the actuator loads and terminal consumption when dividing the station into protected power-feed segments.

EtherCAT process data

Bit width in the process image

8 outputs

Distributed clocks

–

Configuration

no address or configuration setting

Channel LEDs show the commanded output state

The channel LEDs indicate output state. Electronic short-circuit protection does not add the controller-visible diagnostic process image of EL2014 or EL203x. Match the selected terminal’s process image in TwinCAT rather than treating the channel count as its complete interface.

An EtherCAT terminal, not a standalone network device

Install the EL terminal in a compatible EtherCAT terminal station behind its coupler or controller and scan/configure the terminal in TwinCAT. The terminal communicates through the E-bus side contacts; it does not have its own RJ45 Ethernet port. Provide a station end terminal and the required power feeds as part of the station assembly.

Set communication-loss behavior deliberately

The SyncManager watchdog monitors process-data communication. Configure the watchdog and output behavior for the machine before commissioning; disabling a watchdog to maintain outputs changes the communication-loss response. A standard EL digital-output terminal is not a TwinSAFE safety-output terminal.

EL housing and environment

Dimensions (W x H x D)

12 mm x 100 mm x 68 mm

Weight

approx. 70 g

Installation

on 35 mm DIN rail, conforming to EN 60715 with lock

Material

polycarbonate

Operating temperature

-25…+60°C

Storage temperature

-40…+85°C

Relative humidity

95%, no condensation

Protection

IP20; install in a suitable cabinet

EL conductor connection limits

EL conductor connection limits
Parameter / conditionSolid wireStranded wireWire with ferrule
Conductor cross-section0.08–2.5 mm²0.08–2.5 mm²0.14–1.5 mm²
AWG range28–1428–1426–16
Stripping length8–9 mm8–9 mm8–9 mm

Values are for the EL spring terminal, not the ES pluggable wiring level.

Join the terminal station with the power isolated

Mount on a 35 mm DIN rail, engage the side slot/key connection and the rail lock, and preserve the E-bus and power-contact alignment. The EL terminal has a fixed spring wiring level operated by a screwdriver; ES is the separate pluggable-wiring version. Disconnect power before installing, removing or rewiring station terminals.

Cabinet design includes terminal and actuator heating

Use the operating-temperature range with the documented mounting conditions and load current. IP20 provides no weatherproof field enclosure. Space, ventilation, power-feed protection and the complete station’s current budget remain installation decisions, not features supplied by one output terminal.

Sourcing and order support

Order the exact product and condition your project requires, with assistance from quotation through delivery.

Exact product identification

Your quotation references the complete manufacturer part number to keep the requested product clear.

Condition options

Tell us whether you need new original, new surplus, used, refurbished or repaired equipment.

International delivery

Shipping options are prepared around your destination, quantity and requested delivery date.

Documentation support

Access available manufacturer product data, manuals and certificates associated with the order number.