Schneider Electric Modicon M340 Standard Processor Modules
Schneider Electric Modicon M340 standard processor modules. Compare five CPU configurations by memory, system I/O capacity, serial Modbus, Ethernet and CANopen; shared X80 I/O, racks and power supplies remain separate components.
View productsFive standard M340 CPU configurations
Choose the embedded communication combination and controller capacity. This collection covers the five selected standard processors, excluding old 2010/2030 references, H/CL variants, complete kits and X80 system components.
Showing 1–5 of 5

PLCs and control systems
Schneider Electric BMXP341000 Modicon M340 Processor
BMXP341000
New Original
$365.05

PLCs and control systems
Schneider Electric BMXP342000 Modicon M340 Processor
BMXP342000
New Original
$741.00

PLCs and control systems
Schneider Electric BMXP3420102 Modicon M340 Processor
BMXP3420102
New Original
$1,992.60

PLCs and control systems
Schneider Electric BMXP342020 Modicon M340 Processor
BMXP342020
New Original
$2,511.00

PLCs and control systems
Schneider Electric BMXP3420302 Modicon M340 Processor
BMXP3420302
New Original
$883.00
Capacity and embedded communications
These are CPU modules for a separately configured rack system. I/O totals describe system capability rather than onboard field terminals.
BMXP341000
serial Modbus; 2048 KB RAM, 512 discrete/128 analog capacity. USB programming; separate rack and I/O required.
BMXP342000
serial Modbus; 4096 KB RAM, 1024 discrete/256 analog capacity. USB programming; separate rack and I/O required.
BMXP3420102
serial Modbus + CANopen; 4096 KB RAM, 1024 discrete/256 analog capacity. USB programming; separate rack and I/O required.
BMXP342020
serial Modbus + Ethernet; 4096 KB RAM, 1024 discrete/256 analog capacity. USB programming; separate rack and I/O required.
BMXP3420302
Ethernet + CANopen; 4096 KB RAM, 1024 discrete/256 analog capacity. USB programming; separate rack and I/O required.
Choose the CPU as part of a system
Capacity, communication ports, rack power and application storage have separate roles.
- 01
Match the embedded interfaces
1000/2000 use serial Modbus; 20102 adds CANopen; 2020 adds Ethernet; 20302 combines Ethernet and CANopen without an embedded serial link.
- USB programming is fitted on all five.
- Ethernet and serial RJ45 sockets have different electrical functions.
- 02
Treat I/O counts as system limits
The 1000 CPU tier manages up to 512 discrete / 128 analog points; the other four up to 1024 / 256 through separately selected I/O modules.
- Rack/module density and power constrain the usable system.
- Shared X80 I/O does not become part of the CPU package.
- 03
Select the rack and supply
The CPU draws power through its backplane. Select a compatible rack and power supply, then calculate all module loads.
- Average CPU currents range 72–135 mA at 24 V.
- CPU heat loss is 1.7–3.2 W without powered external devices.
- 04
Plan the application and card
Use Control Expert and the exact CPU configuration. The supplied application card is distinct from optional MPF file-storage cards.
- Hardware does not include a software license.
- Retain the supported project/firmware and backup for replacement work.